Paradigm Cooling
Paradigm Cooling
  • 26
  • 47 432
A guide to the top air conditioning installation companies in Cape Town
Looking for the best air conditioning installation companies in Cape Town? 🌬️ This guide is here to help you make an informed decision! At Paradigm Cooling, we’ve researched and compiled a list of the top-rated air conditioning service providers in the Mother City. Whether you’re a homeowner or a business owner, finding the right company is key to ensuring a reliable, efficient, and professional installation experience.
In this video, we highlight:
✅ The leading air conditioning installers in Cape Town.
✅ Key factors to consider when choosing an installation company.
✅ Tips for ensuring long-term performance and efficiency for your air conditioning system.
💡 Ready to upgrade your indoor comfort? Watch now to discover trusted names in the industry and get expert insights into making the best choice for your cooling needs.
🌟 **Don’t forget to like, comment, and subscribe to Paradigm Cooling for more expert advice, tips, and recommendations on all things air conditioning!**
มุมมอง: 32

วีดีโอ

How to test a start capacitor on an HVAC system
มุมมอง 76914 วันที่ผ่านมา
Learn how to test a start capacitor on an HVAC system like a pro! In this step-by-step guide, we’ll show you how to diagnose and troubleshoot capacitor issues, ensuring your air conditioner or heating system runs smoothly. Whether you're an HVAC technician or a DIY enthusiast, this tutorial will help you identify common signs of a failing start capacitor and use a multimeter to test it accurate...
How to correctly size your air conditioning system with Paradigm Cooling's HVAC Heatload Calculator
มุมมอง 22หลายเดือนก่อน
Are you struggling to find the right air conditioning size for your home or business? Oversized or undersized units can lead to energy inefficiency, higher costs, and uncomfortable spaces. In this step-by-step guide, we’ll show you exactly how to use the Paradigm Cooling HVAC Heatload Calculator , available on our website, to size your AC like a pro! 📌 In this video, you’ll learn: - Why proper ...
How to operate an LG Artcool infrared remote controller
มุมมอง 125หลายเดือนก่อน
Discover how to use the LG Artcool Air Conditioner remote controller with our easy step-by-step guide! In this video, we’ll show you how to operate all the essential functions of this sleek and efficient air conditioning system, including: ✅ Turning the unit on and off ✅ Switching between cooling, heating, dehumidifying, and fan-only modes ✅ Adjusting temperature, fan speed, and airflow directi...
Refrigeration Trade Test Tasks: How to do an efficiency test on a compressor
มุมมอง 1872 หลายเดือนก่อน
Are you preparing for the commercial refrigeration trade test? Understanding how to perform a compressor efficiency test is crucial for ensuring optimal system performance and passing the test with confidence! In this video, we walk you through a step-by-step guide on testing the efficiency of a refrigeration compressor, covering everything from preparation and safety measures to analyzing resu...
How to use a valve core removal tool
มุมมอง 4.8K2 ปีที่แล้ว
How to use a valve core removal tool
How to use a nitrogen regulator
มุมมอง 22K2 ปีที่แล้ว
How to use a nitrogen regulator
Flaring and swaging basics for copper tubing
มุมมอง 1.2K2 ปีที่แล้ว
Flaring and swaging basics for copper tubing
How to recover refrigerant from a HVACR system
มุมมอง 7502 ปีที่แล้ว
How to recover refrigerant from a HVACR system
JB Industries Vacuum Pump oil change
มุมมอง 1.6K2 ปีที่แล้ว
JB Industries Vacuum Pump oil change
Refrigeration Evacuation secrets I wish my lecturers told me
มุมมอง 2502 ปีที่แล้ว
Refrigeration Evacuation secrets I wish my lecturers told me
Refrigeration Basics : How a refrigeration system works
มุมมอง 2112 ปีที่แล้ว
Refrigeration Basics : How a refrigeration system works
Refrigeration Trade Test Tasks : Testing a 3 phase electrical motor
มุมมอง 9K2 ปีที่แล้ว
Refrigeration Trade Test Tasks : Testing a 3 phase electrical motor
Samsung DVM S, E - 213 and E - 215 error code repair.
มุมมอง 4K2 ปีที่แล้ว
Samsung DVM S, E - 213 and E - 215 error code repair.
Paradigm Cooling 9000BTU Midwall Split installation
มุมมอง 1473 ปีที่แล้ว
Paradigm Cooling 9000BTU Midwall Split installation
An introduction to Paradigm Cooling
มุมมอง 1223 ปีที่แล้ว
An introduction to Paradigm Cooling

ความคิดเห็น

  • @minnthant1834
    @minnthant1834 4 หลายเดือนก่อน

    E 458 error repair

  • @Alex-y2p5u
    @Alex-y2p5u 5 หลายเดือนก่อน

    great video thanks

  • @PrabakaranN-d9u
    @PrabakaranN-d9u 6 หลายเดือนก่อน

    Will nitrogen cylider blast if regulator is not connected properly..? How to avoid this..? Pleasee reply

    • @paradigmcooling8497
      @paradigmcooling8497 6 หลายเดือนก่อน

      Hello. The nitrogen cylinder won't explode, but incorrect use of the regulator can cause an explosion outside of the cylinder. You can avoid this by making sure that the regulator is properly connected to the cylinder, without any leaks, and make sure that the pressure setting on the regulator does not exceed the safe operating pressure of the vessel that the nitrogen is being fed into. You can consult the manufacturer's specification literature for specific values.

  • @michaelamay9714
    @michaelamay9714 7 หลายเดือนก่อน

    Whats the difference between the left gauge and right gauge?

    • @paradigmcooling8497
      @paradigmcooling8497 7 หลายเดือนก่อน

      Hi Michael. The left gauge shows the pressure leaving the regulator, while the right gauge shows the pressure in the cylinder.

    • @michael931
      @michael931 3 หลายเดือนก่อน

      ​@@paradigmcooling8497 why does the right hand gauge always show 0 PSI in the video?

  • @makhadzimakhams2419
    @makhadzimakhams2419 7 หลายเดือนก่อน

    Can you also add single phase motor test

    • @paradigmcooling8497
      @paradigmcooling8497 7 หลายเดือนก่อน

      Hi Makhadzi. That's a great idea. We have added it to our list of requests.

  • @jalicecopeland5407
    @jalicecopeland5407 11 หลายเดือนก่อน

    How do you check to see how much pressure is inside before using ?

    • @paradigmcooling8497
      @paradigmcooling8497 9 หลายเดือนก่อน

      Hi Jalice. The nitrogen regulator has two gauges fitted to it. One gauge reads the pressure in the cylinder and the second gauge shows the output pressure of nitrogen leaving the cylinder. In order to see how much pressure is in the cylinder, you simply have to open the cylinder with the t-style handle on the regulator still closed (as per normal operating procedures), and the high pressure gauge reading will rise to represent the cylinder pressure. The low pressure gauge should show zero at this point with the regulator still being closed. In this video, you will notice that the cylinder pressure is very low, hence the high pressure gauge showing very close to zero.

  • @joeoehm4341
    @joeoehm4341 ปีที่แล้ว

    Can I use the Schrader valve core remover right at the beginning? For new systems, practically BEFORE evacuation? For older systems, in cooling mode, but still switched off (there is a slightly pressure).

  • @DavidMoloi-y4m
    @DavidMoloi-y4m ปีที่แล้ว

    Thank you for the info. Can you please post the rest of the tasks.

    • @paradigmcooling8497
      @paradigmcooling8497 ปีที่แล้ว

      Thank you for your comment. We will be uploading the video on the efficiency test on a compressor in the next week or so.

  • @safetyalways7788
    @safetyalways7788 ปีที่แล้ว

    What did you connect the yellow hose from the valve core remover tool to?

    • @paradigmcooling8497
      @paradigmcooling8497 ปีที่แล้ว

      Hi @safetyalways7788. The yellow hose on the video is connected to my digital vacuum guage. Now it is important that the hose used be rated for vacuum, or alternatively just use a Micron Coupler, which is the industry best practice right now.

    • @safetyalways7788
      @safetyalways7788 ปีที่แล้ว

      @@paradigmcooling8497 ok

  • @garrybaker6485
    @garrybaker6485 ปีที่แล้ว

    This is the best video made on the topic. Appreciate you. My only question at this point - the manufacturer specifies pouring oil down the vacuum inlet port during the oil change. Can you demonstrate that part of the process?

    • @paradigmcooling8497
      @paradigmcooling8497 ปีที่แล้ว

      Thank you Gary. Yes the charging of oil through the vacuum inlet port is an important part of the oil flushing process when the replaced oil is badly contaminated and we should definitely do a video on the process. Thank you for the suggestion and we will certainly add it to our production list.

  • @amgari007
    @amgari007 ปีที่แล้ว

    Thank you for the video. I have an argon/co2 regulator .Can I use it with nitrogen since fits to tank if I change the left low gauge to 100-600 psi one? Thanks.

    • @paradigmcooling8497
      @paradigmcooling8497 ปีที่แล้ว

      That's a very good question. Conventional wisdom suggests that you could theoretically use an argon/co2 regulator for nitrogen applications provided that the fittings match the cylinder being used and that the maximum pressure threshold of the gauges is sufficient to manage the cylinder pressure. You could of course add additional adapters and fit new gauges to make the regulator compatible, but my personal preference is to use the correct regulator for the gas it was originally designed for. It is also worth a mention that the pressure regulation legislature in your country may prohibit such modifications under its safety laws. I would research them thoroughly before making any changes to the equipment. thank you for your question and be safe.

    • @amgari007
      @amgari007 ปีที่แล้ว

      @@paradigmcooling8497 Thank you very much for the reply. Best regards.

  • @candidoespinal2466
    @candidoespinal2466 ปีที่แล้ว

    Can you do a video pulling a vacuum with this pump on a condenser coil

    • @paradigmcooling8497
      @paradigmcooling8497 ปีที่แล้ว

      Yes we have a video in the works that involves a vaccuum decay test on a condenser, using this exact pump, which may be what you are looking for.

  • @lugongguo8125
    @lugongguo8125 ปีที่แล้ว

    Thanks for sharing the video. I will test pressure gauges with a nitrogen cylinder and regulator valve with an increase and decrease dial not a handle like yours. Do I have to turn the dial to the decrease side all the way before I open the shut-off valve of the cylinder? or it doesn't matter. Any safety tips? After I test each pressure gauge, do I have to shut off the cylinder? Thanks again. 👍

    • @paradigmcooling8497
      @paradigmcooling8497 ปีที่แล้ว

      Hello there. Yes it is best that you leave the regulator closed all the way before opening the cylinder. This is just to make sure that the pressure coming through the line doesn't exceed the maximum pressure tolerance of the guage that you are testing. You can gradually open the regulator until you get to the desired test pressure. Also, if you are testing multiple guages then it isn't necessary to close the cylinder after each test. You can just close the regulator after each test until all the tests are complete. Upon completion of all the tests, you can then close the cylinder as a final step.

  • @damienlb3551
    @damienlb3551 ปีที่แล้ว

    Does the regulator have to be shut before opening the cylinder valve ?

    • @paradigmcooling8497
      @paradigmcooling8497 ปีที่แล้ว

      Yes, it's best to do it that way in order to properly regulate the pressure coming out of the cylinder. It allows you to slowly raise the pressure to the desired level without the risk of rupturing the system being filled. I have seen a technician pre-set the regulator for a pressure test on an evaporator and upon opening the cylinder, the evaporator immediately ruptured because a part of system was weakened due to wear and tear. Luckily no one got hurt but the bang quickly cleared the building. Lol

  • @joaobandarra5044
    @joaobandarra5044 2 ปีที่แล้ว

    You have the eva in thermistor damaged in the unit 13

  • @ediwardyeremia7916
    @ediwardyeremia7916 2 ปีที่แล้ว

    Excellent tutorial , we need more boss

  • @30mAkills
    @30mAkills 2 ปีที่แล้ว

    Excellent tutorial. It would have been more useful if you have provided meggering tip for thermistor protected motors.

    • @paradigmcooling8497
      @paradigmcooling8497 2 ปีที่แล้ว

      That is a great tip, thank you. We will definitely look at making that video in the near future....

  • @andrzejbowhall2170
    @andrzejbowhall2170 2 ปีที่แล้ว

    I'm going to check out your channel now! New fan :). Easy video ranking > P-R-O-M-O-S-M!!