Construction: Hanging Drywall on a Vaulted Ceiling with Gadgets; L brackets and rotating step clip
มุมมอง 1103 หลายเดือนก่อน
Construction: Hanging Drywall on a Vaulted Ceiling with Gadgets; L brackets and 360 degree rotating step clip
Installation of Cellulose Greenfiber Insulation: First all-in-one cellulose insulation RE:IMBD LLC
มุมมอง 1683 หลายเดือนก่อน
Installation of Cellulose Greenfiber Insulation: First all-in-one cellulose insulation RE:IMBD LLC Cellulose as a compliment to foam insulation. We think all insulation is dangerous to install and so the install workers should use a mask, eye goggles and protective suit. However, we think cellulose insulation is less dangerous compared to rock wool or fiberglass. About This Product SANCTUARY by...
Installation of Cellulose Greenfiber Insulation: First all-in-one cellulose insulation RE:IMBD LLC
มุมมอง 204 หลายเดือนก่อน
Installation of Cellulose Greenfiber Insulation: First all-in-one cellulose insulation RE:IMBD LLC
Installation of Cellulose Greenfiber Insulation: First all-in-one cellulose insulation RE:IMBD LLC
มุมมอง 114 หลายเดือนก่อน
Installation of Cellulose Greenfiber Insulation: First all-in-one cellulose insulation RE:IMBD LLC
Installation of Cellulose Greenfiber Insulation: First all-in-one cellulose insulation RE:IMBD LLC
มุมมอง 504 หลายเดือนก่อน
About This Product SANCTUARY by Greenfiber can be installed in attics, walls, floors and ceilings to significantly improve the comfort, safety and well-being provided by any home. This is the first All-In-One cellulose insulation that can be blown-in or spray-applied, and it's suitable for all climates and conditions. Capable of reducing sound power by 60% and heating and cooling costs by up to...
Electric: Identifying and Repairing a “Ground Fault Neutral” and/ or a “Ground Only Fault”.
มุมมอง 1.3K4 หลายเดือนก่อน
Electric: Identifying and Repairing a “Ground Fault Neutral” and/ or a “Ground Only Fault”. Notice that a "Ground Fault Neutral" error reading could mean the neutral wires are not connected or (suprise) that the ground wires are not tied together properly. Hope this helps you evaluate both possible errors. DIY. Double gang electrical box with dishwasher outlet and garbage disposal outlet with s...
Insulation Installation. Cellulose. High Fire Resistant Properties. Safety of Use. RE:IMBD LLC
มุมมอง 624 หลายเดือนก่อน
Insulation Installation. Cellulose. (Paper treated with fire resistant materials) High Fire Resistant Properties. Safety of Use. Cellulose is made up of a series of sugar molecules linked together in a long chain. Since it is a fiber that makes up plant cell walls, it's found in all plant foods. When you eat food that contains it, cellulose stays intact as it passes through your small intestine...
Drywall, Ceiling Installation, Cutting Out Holes for Can Lights RE:IMBD LLC
มุมมอง 126 หลายเดือนก่อน
Drywall, Ceiling Installation, Cutting Out Holes for Can Lights RE:IMBD LLC
Construction; Keeping Hands Warm; 3 Layer System, Thermal Socks with Finger Cut-Outs, RE:IMBD LLC
มุมมอง 566 หลายเดือนก่อน
Construction; Keeping Hands Warm; 3 Layer System, 1. First Layer: Thermal Socks with Finger Cut-Outs; 2. Second Layer: Knitted Gloves with Half Fingers; 3. Third Layer: Work Gloves with Rubber Palms and Fingers So Worker Can Manipulate and Work With Tools: RE:IMBD LLC
Drywall Installation at Ceiling with Hole Cut Outs for Can Lights with Only One Worker
มุมมอง 146 หลายเดือนก่อน
Drywall Installation at Ceiling with Hole Cut Outs for Can Lights with Only One Worker
Drywall Installation at Ceiling with Hole Cut Outs for Can Lights with Only One Worker
มุมมอง 3046 หลายเดือนก่อน
Drywall Installation at Ceiling with Hole Cut Outs for Can Lights with Only One Worker
Scaffolding DIY Install Drywall 20’ High Foyer Over Stairs; Rolling Lock Wheels; Horizontal Ladder
มุมมอง 367 หลายเดือนก่อน
Scaffolding DIY to Install Drywall at 20’ High Foyer; Rolling Locking Wheels; Horizontal Ladder; “third hand” pole supports to hold and raise drywall into place before screwing it in: stitching horizontal planks into ladder rung with rope; safety harness with rope attached independent of scaffolding; scaffolding built with diagonal shoring in opposite sides of box for light weight strength The ...
Scaffolding DIY Install Drywall 20’ High Foyer Over Stairs; Rolling Lock Wheels; Horizontal Ladder
มุมมอง 627 หลายเดือนก่อน
Scaffolding DIY Install Drywall 20’ High Foyer Over Stairs; Rolling Lock Wheels; Horizontal Ladder
Installing Drywall to Ceiling with Third Hand Pole Supports with Adjustable Handles
มุมมอง 827 หลายเดือนก่อน
Installing Drywall to Ceiling with Third Hand Pole Supports with Adjustable Handles
Scaffolding DIY Install Drywall 20’ High Foyer Over Stairs; Rolling Lock Wheels; Horizontal Ladder
มุมมอง 307 หลายเดือนก่อน
Scaffolding DIY Install Drywall 20’ High Foyer Over Stairs; Rolling Lock Wheels; Horizontal Ladder
Safety Construction; Cement Fiberboard Siding Work; Avoiding Silica Cement Dust Lungs. RE:IMBD LLC
มุมมอง 12ปีที่แล้ว
Safety Construction; Cement Fiberboard Siding Work; Avoiding Silica Cement Dust Lungs. RE:IMBD LLC
Safety Construction; Cement Fiberboard Siding Work; Avoiding Silica Cement Dust Lungs. RE:IMBD LLC
มุมมอง 22ปีที่แล้ว
Safety Construction; Cement Fiberboard Siding Work; Avoiding Silica Cement Dust Lungs. RE:IMBD LLC
Dust Mitigation Box to Protect Lungs from Silica Dust While Cutting Fiber Cement Board. Hardibacker.
มุมมอง 106ปีที่แล้ว
Dust Mitigation Box to Protect Lungs from Silica Dust While Cutting Fiber Cement Board. Hardibacker.
Dust Mitigation Box to Protect Lungs from Silica Dust While Cutting Fiber Cement Board
มุมมอง 18ปีที่แล้ว
Dust Mitigation Box to Protect Lungs from Silica Dust While Cutting Fiber Cement Board
Water Works Chemistry, LLC. General Company Introduction
มุมมอง 12ปีที่แล้ว
Water Works Chemistry, LLC. General Company Introduction
Water Works Chemistry, LLC. General Company Information and Presentation for Water Purifier; Filter
มุมมอง 11ปีที่แล้ว
Water Works Chemistry, LLC. General Company Information and Presentation for Water Purifier; Filter
Excavation: Electrical trench, By Hand Shovel; RE:IMBD LLC
มุมมอง 26ปีที่แล้ว
Excavation: Electrical trench, By Hand Shovel; RE:IMBD LLC
Sheetrock Installation at 1.5” Stud
มุมมอง 35ปีที่แล้ว
Sheetrock Installation at 1.5” Stud
Plumbing: Pro Press (No Weld, No Solder) Copper Connection Fitting for Water Supply . RE:IMBD LLC
มุมมอง 46ปีที่แล้ว
Plumbing: Pro Press (No Weld, No Solder) Copper Connection Fitting for Water Supply . RE:IMBD LLC
Plumbing; Method Cutting ABS Pipe Straight / Flush Pipe Clamp as Guide Close Quarters RE:IMBD LLC
มุมมอง 426ปีที่แล้ว
Plumbing; Method Cutting ABS Pipe Straight / Flush Pipe Clamp as Guide Close Quarters RE:IMBD LLC
Plumbing: Installation of shower control valve, tub spout, shower head. RE: IMBD LLC, IPC, Internat
มุมมอง 81ปีที่แล้ว
Plumbing: Installation of shower control valve, tub spout, shower head. RE: IMBD LLC, IPC, Internat
Plumbing: Installation of shower control valve, tub spout, shower head. RE: IMBD LLC, IPC, Internat
มุมมอง 14ปีที่แล้ว
Plumbing: Installation of shower control valve, tub spout, shower head. RE: IMBD LLC, IPC, Internat
Plumbing: Installation of shower control valve, tub spout, shower head. RE: IMBD LLC, IPC, Internat
มุมมอง 66ปีที่แล้ว
Plumbing: Installation of shower control valve, tub spout, shower head. RE: IMBD LLC, IPC, Internat
Safety Harness w/2 Alternat Clips Ascend Indust. Ladder w/out a Built -In Safety Line: RE:IMBD LLC
มุมมอง 11ปีที่แล้ว
Safety Harness w/2 Alternat Clips Ascend Indust. Ladder w/out a Built -In Safety Line: RE:IMBD LLC

ความคิดเห็น

  • @jimmyhai6840
    @jimmyhai6840 7 วันที่ผ่านมา

    WTH is going on ? Lol

  • @SRCardow1
    @SRCardow1 29 วันที่ผ่านมา

    Not sure where you are but never heard of a construction home builder being allowed to do the work. In NH exception states: that a homeowner from making electrical installations in or about a single-family residence owned and occupied by him or her or to be occupied by him or her as his or her bona fide personal abode. In other words, they own and live in and need to comply with NEC 70 as adopted by the state including permits. Otherwise, someone buying a home could be at risk and go back on you if you can't prove a licensed electrician did the work.

  • @bartmormino907
    @bartmormino907 หลายเดือนก่อน

    That work would never pass in my area, it does not meet code. UPC or IRC would not allow that work. What state are you in?

    • @user-tw4ku2fl9v
      @user-tw4ku2fl9v 20 วันที่ผ่านมา

      Hi sir, i need help in installing dwv. Specifically for soil stack. It's a 3 storey concrete building. 1. Is it better to install outside or inside? Embedded to wall or just beside it? 2. Is it better to embed it to an CHB wall? Or outside the wall just beside it? And if it's embedded? Where going to embed it to an beam or column right? So the vertical pipe will bend to the beam and bend again embeding it to the wall? Is going to have like an 2 45 deg. Bend on a beam?

  • @serezhka2943
    @serezhka2943 หลายเดือนก่อน

    Thank you!

  • @donaldblank8873
    @donaldblank8873 2 หลายเดือนก่อน

    All fittings below the flood rim Of the highest fixture have to be long sweet fittings. Vent fittings and drain fittings included. Clean out must be at floor level or higher

    • @user-tw4ku2fl9v
      @user-tw4ku2fl9v 20 วันที่ผ่านมา

      Hi sir, i need help in installing dwv. Specifically for soil stack. It's a 3 storey concrete building. 1. Is it better to install outside or inside? Embedded to wall or just beside it? 2. Is it better to embed it to an CHB wall? Or outside the wall just beside it? And if it's embedded? Where going to embed it to an beam or column right? So the vertical pipe will bend to the beam and bend again embeding it to the wall? Is going to have like an 2 45 deg. Bend on a beam?

  • @LoicKamto
    @LoicKamto 3 หลายเดือนก่อน

    Trap dip not trap weir👍

  • @lukewadel3675
    @lukewadel3675 3 หลายเดือนก่อน

    Thanks, great tip!

  • @bornfree1852
    @bornfree1852 4 หลายเดือนก่อน

    Even Ray Charles can see this wont pass inspection.

  • @user-dy5tm5cw2j
    @user-dy5tm5cw2j 4 หลายเดือนก่อน

    To many fittings

  • @user-dy5tm5cw2j
    @user-dy5tm5cw2j 4 หลายเดือนก่อน

    No need for that

  • @artgrathartgrath3451
    @artgrathartgrath3451 4 หลายเดือนก่อน

    Was that a 2" for the toilet?

  • @tacticaltal
    @tacticaltal 4 หลายเดือนก่อน

    The tester is showing an open "groundED neutral", or simply "neutral" conductor. The neutral is considered a grounded conductor because it's grounded at the main panel. A broken groundING conductor (the bare) will not prevent the circuit from working, so tying all those together, and making it work, was simply a coincidence. Somewhere the white neutral was loose, and you fixed it without knowing it. 🙂

    • @killer2600
      @killer2600 4 หลายเดือนก่อน

      You need to know your test tool, the tester (Klein RT250) is showing an open ground AND neutral. As for this video, it scares me that someone is doing wiring and doesn't know all the grounds are tied together not just to make the tester happy but as part of proper electrical work. I'm glad this isn't my kitchen because yes the tester is happy but I don't trust the actual wiring issue was fixed instead of covered up.

  • @hepparade
    @hepparade 5 หลายเดือนก่อน

    It unfortunate we couldnt roll the main drain line in the next bay to the right to hit the vent without rollibg flat. In our locale flat vents are required to be the next min pipe dia up servicing the drain load, pitched to drain, and require drainage standard fittings (those vent 90's- no; vert to horizontal- long sweep) until you are 6" above the highest flood rim of the group or 42" above FF which ever is higher. Your bath drain could be be considered an s trap if your drain arm changes horizontal plane before venting without increasing pipe size. In the future hit yor vent before your drainage arm changes out of horizontal. Planing is everything.

    • @user-tw4ku2fl9v
      @user-tw4ku2fl9v 20 วันที่ผ่านมา

      Hi sir, i need help in installing dwv. Specifically for soil stack. It's a 3 storey concrete building. 1. Is it better to install outside or inside? Embedded to wall or just beside it? 2. Is it better to embed it to an CHB wall? Or outside the wall just beside it? And if it's embedded? Where going to embed it to an beam or column right? So the vertical pipe will bend to the beam and bend again embeding it to the wall? Is going to have like an 2 45 deg. Bend on a beam?

  • @hepparade
    @hepparade 5 หลายเดือนก่อน

    It unfortunate we couldnt roll the main drain line in the next bay to the right to hit the vent without rollibg flat. In our locale flat vents are required to be the next min pipe dia up servicing the drain load and require drainage fitings until you are 6" abovr the highest flood rim of yhe group or 42" above FF which ever is higher.

    • @user-tw4ku2fl9v
      @user-tw4ku2fl9v 20 วันที่ผ่านมา

      Hi sir, i need help in installing dwv. Specifically for soil stack. It's a 3 storey concrete building. 1. Is it better to install outside or inside? Embedded to wall or just beside it? 2. Is it better to embed it to an CHB wall? Or outside the wall just beside it? And if it's embedded? Where going to embed it to an beam or column right? So the vertical pipe will bend to the beam and bend again embeding it to the wall? Is going to have like an 2 45 deg. Bend on a beam?

  • @johnpeters9903
    @johnpeters9903 5 หลายเดือนก่อน

    At 0:29 both horizontal dry (unwashed) vents below flood rim of fixture defy proper code.

  • @HomeBuildingDIY.RE.IMBDLLC
    @HomeBuildingDIY.RE.IMBDLLC 5 หลายเดือนก่อน

    Home Depot 60 lb bag cement 2 years ago, Utah

  • @chriscolameco6850
    @chriscolameco6850 5 หลายเดือนก่อน

    Where are you getting that for $5/bag

  • @archiebarnett2526
    @archiebarnett2526 5 หลายเดือนก่อน

    "Promosm" 💖

  • @dan9809
    @dan9809 5 หลายเดือนก่อน

    Where does the washing machine connect to it? Or does it work by itself without connecting the washer?

  • @richwinegar5517
    @richwinegar5517 5 หลายเดือนก่อน

    This guy has no clue

  • @ncooty
    @ncooty 5 หลายเดือนก่อน

    That's not the weir. The weir is the bottom of the outflow pipe, which is the water level when the P trap is full.

  • @rudyromano2402
    @rudyromano2402 6 หลายเดือนก่อน

    Where's your trap keep fumes out ?

  • @HomeBuildingDIY.RE.IMBDLLC
    @HomeBuildingDIY.RE.IMBDLLC 6 หลายเดือนก่อน

    Look up was an S trap is; and remember it violates code; so distance between the san tee and p trap is necessary

  • @YB-eg3rj
    @YB-eg3rj 6 หลายเดือนก่อน

    Is there a code that requires a minimum distance between the trap and san tee? Or can it be tied in directly? Thank you

    • @correyy
      @correyy 5 หลายเดือนก่อน

      2x the diameter of the pipe. So 4 inch of straight for 2" pipe

  • @robertopalacios9521
    @robertopalacios9521 6 หลายเดือนก่อน

    No vent

  • @richwinegar5517
    @richwinegar5517 6 หลายเดือนก่อน

    WARNING! Only experts should be allowed on TH-cam. This guy scares me, I'm concerned for the family who lives there.

    • @HomeBuildingDIY.RE.IMBDLLC
      @HomeBuildingDIY.RE.IMBDLLC 6 หลายเดือนก่อน

      We welcome constructive evaluation. If you think the system is configured or wired wrong; can you specify what is wrong and how you think it should be changed to compliance and safety.

  • @phazelvosfreqdetector7580
    @phazelvosfreqdetector7580 6 หลายเดือนก่อน

    Those canless lights are sure looking good right about now.

  • @omegaplumbing
    @omegaplumbing 7 หลายเดือนก่อน

    Uh Oh stickers on the fittings thats your first give away...lol

  • @omegaplumbing
    @omegaplumbing 7 หลายเดือนก่อน

    In my 29 years of plumbing In CO MA CT NYC and CA, Ive seen more crazy stuff on TH-cam than I have ever seen in the field. Where are these people and what state is this?

    • @user-tw4ku2fl9v
      @user-tw4ku2fl9v 20 วันที่ผ่านมา

      Hi sir, i need help in installing dwv. Specifically for soil stack. It's a 3 storey concrete building. 1. Is it better to install outside or inside? Embedded to wall or just beside it? 2. Is it better to embed it to an CHB wall? Or outside the wall just beside it? And if it's embedded? Where going to embed it to an beam or column right? So the vertical pipe will bend to the beam and bend again embeding it to the wall? Is going to have like an 2 45 deg. Bend on a beam?

  • @verywendyyoga
    @verywendyyoga 7 หลายเดือนก่อน

    Impressive work~

  • @coltonmorquecho6665
    @coltonmorquecho6665 7 หลายเดือนก่อน

    I just threw up on my phone

  • @brandifree2livlafluv848
    @brandifree2livlafluv848 9 หลายเดือนก่อน

    What a joke and a total waste of time watching this! lol

  • @garycasper2929
    @garycasper2929 10 หลายเดือนก่อน

    Always remember to check with local codes. And always remember, you tube is worldwide.

  • @Antonomie
    @Antonomie 11 หลายเดือนก่อน

    No man, we can’t see.

  • @shadin6068
    @shadin6068 ปีที่แล้ว

    Loved this!

  • @KaiKiko__Foxkit
    @KaiKiko__Foxkit ปีที่แล้ว

    1099.00 for the lift. Ouch!!!!😂

  • @ricardogutierrez2173
    @ricardogutierrez2173 ปีที่แล้ว

    weird installation here in California is a HUGE BIG NO NO, first able buddy for a 400amp main service is required a 1/0 copper wire. one of the guys said hope this guy is not who wire my house lol true.

  • @HomeBuildingDIY.RE.IMBDLLC
    @HomeBuildingDIY.RE.IMBDLLC ปีที่แล้ว

    What is a "ufer"? What does that stand for?

    • @HomeBuildingDIY.RE.IMBDLLC
      @HomeBuildingDIY.RE.IMBDLLC ปีที่แล้ว

      A “Ufer” ground is slang for what the National Electrical Code (NEC) addresses as a concrete-encased grounding electrode. The term “Ufer” does not appear in the Code, but many in the industry use it.

  • @electrictim
    @electrictim ปีที่แล้ว

    This was not done right. Why make a tutorial if you don't know what you're talking about?

    • @HomeBuildingDIY.RE.IMBDLLC
      @HomeBuildingDIY.RE.IMBDLLC ปีที่แล้ว

      We think the work was done correctly. We welcome productive criticism. If you think the work was done incorrectly; please cite and reference the code you think it violates; and present a statement on what is wrong and how it should be corrected to adhere to code.

    • @electrictim
      @electrictim ปีที่แล้ว

      Does not comply with NEC 250.52 and other common electrical codes. Conductor is not continuous. If you're using the ground rods as they're supposed to be used, you cannot cut them to shorter lengths. If the rods are just used as supports to hold the conductor so that it is a concrete encased electrode (which you didn't mention, so we have to assume that is not the case) then there needs to be room around the conductor to be properly encased in concrete. The screws holding the ground bar onto the panel are coarse type which cannot properly get 2 threads holding onto the metal frame of the panel so it is not properly attached. If you're making a tutorial, you are saying this is the right way, or at least A right way to do it. This is misleading to others who don't know any better.

    • @electrictim
      @electrictim ปีที่แล้ว

      Not only is this installation not code, it is not safe. Once your screws and splices fail (which they will), you have no more ufer because odds are your water pipe is ran in pec line and cannot act as a ufer either.

  • @NYC_Plumber_Guy
    @NYC_Plumber_Guy ปีที่แล้ว

    💪🏻💪🏻 solid

  • @chriseckelberg7467
    @chriseckelberg7467 ปีที่แล้ว

    Leave the plumbing for a licensed plumber!

  • @kevinhornbuckle
    @kevinhornbuckle ปีที่แล้ว

    Nice work!

  • @SteadyBark96720
    @SteadyBark96720 ปีที่แล้ว

    On tonight’s episode of…Amateur Hour

    • @user-tw4ku2fl9v
      @user-tw4ku2fl9v 20 วันที่ผ่านมา

      Hi sir, i need help in installing dwv. Specifically for soil stack. It's a 3 storey concrete building. 1. Is it better to install outside or inside? Embedded to wall or just beside it? 2. Is it better to embed it to an CHB wall? Or outside the wall just beside it? And if it's embedded? Where going to embed it to an beam or column right? So the vertical pipe will bend to the beam and bend again embeding it to the wall? Is going to have like an 2 45 deg. Bend on a beam?

  • @bradhaenitsch1145
    @bradhaenitsch1145 ปีที่แล้ว

    Finally someone knows how to install a drip leg thank you

  • @user-nb2bj8sw5y
    @user-nb2bj8sw5y ปีที่แล้ว

    That’s some crappy pex work 🤣

    • @macanina100
      @macanina100 9 หลายเดือนก่อน

      Glad I wasent the only one who noticed. Never knew they had a device like that to install for a floor drain. What’s it callled?

    • @jimmyhai6840
      @jimmyhai6840 7 วันที่ผ่านมา

      It’s called the trap primer valve. The vertical distance from a plumbing fixture outlet to a trap weir should not exceed 24 inches and the horizontal distance should not exceed 30 inches. The vertical distance should also be as short as possible. If it’s too far it’s not gonna work.

  • @dominickshayne380
    @dominickshayne380 ปีที่แล้ว

    *Promo SM* 😉

  • @Sandy_.__
    @Sandy_.__ ปีที่แล้ว

    Bro I need hydraulic cement lifting machine can u help me where I could search

  • @Sandy_.__
    @Sandy_.__ ปีที่แล้ว

    Bro I need this

    • @HomeBuildingDIY.RE.IMBDLLC
      @HomeBuildingDIY.RE.IMBDLLC ปีที่แล้ว

      handtrucks2go.com/Electric-Hand-Truck/?gclid=Cj0KCQjwxYOiBhC9ARIsANiEIfbwOIKL5hcfR7cQcD6UCpdIuj48i9V88XtkBS4ukomyV3214NmVwQ8aAs0cEALw_wcB

  • @robertbeck5524
    @robertbeck5524 ปีที่แล้ว

    So u put a clean out in the ceiling 😢 and u installed a trap with union in ceiling that will leak at some time I don’t know where u r in the U.S but your inspector must be your brother or doesn’t know the code

  • @user-tn2hg3rd7h
    @user-tn2hg3rd7h ปีที่แล้ว

    you can't fall more than your pipe diameter before venting a trap. your tub is a full blown S-trap and would not pass inspection. you used so much pipe individually venting all of the fixtures. You could've wet vented the entire bathroom group and went up the wall with 1 continuous waste and vent saving way more pipe and fittings. How i wouldve done it: 90 under the water closet, run back to the wall, install a 3X3X2 wye, shoot through the floor joist, install a 2 X 2 X 1 1/2 wye (2" for the wet vent to continue up the wall to the Lav, and the 1 1/2 branch to catch the bath tub) And then 90 up into the floor/ wall with my wet vent upstairs. install a 2 X 1 1/2 X 1 1/2 TY and shoot over in the wall and 90 out to catch my Lav. Then run the SINGLE continuous waste vent pipe up to the attic tying into my main stack if it is in close enough proximity. If not, I would put it through the roof by itself upsizing to 3" before terminating to open air. This way would save you tons of pipe and fittings and it would look a ton better. Remind you this is dependent on the Ontario plumbing code and it is how I would've done it in my jurisdiction.

    • @johnpeters9903
      @johnpeters9903 5 หลายเดือนก่อน

      Exactly

    • @user-tw4ku2fl9v
      @user-tw4ku2fl9v 20 วันที่ผ่านมา

      Hi sir, i need help in installing dwv. Specifically for soil stack. It's a 3 storey concrete building. 1. Is it better to install outside or inside? Embedded to wall or just beside it? 2. Is it better to embed it to an CHB wall? Or outside the wall just beside it? And if it's embedded? Where going to embed it to an beam or column right? So the vertical pipe will bend to the beam and bend again embeding it to the wall? Is going to have like an 2 45 deg. Bend on a beam?