Cold Flash AC
Cold Flash AC
  • 28
  • 134 289
How to access tech settings on aaon thermostat
DISCLAIMER
DO NOT TRY THIS AT HOME OR ON THE FIELD IF YOU ARE NOT AN HVAC PROFESSIONAL
(th-cam.com/channels/Fsw_y8cwA7UVXbIojXqS3A.html )
//Recommended videos:▶️Compressor running backwards th-cam.com/video/dFMEC9xWwtk/w-d-xo.html
▶️ Hacked Customer filterth-cam.com/video/jSB3_nRA8YU/w-d-xo.html
▶️ ac compressor isn't starting ! th-cam.com/video/RMfP3fdBbg0/w-d-xo.html
Check this products
www.icybreeze.com?afmc=kt
//Let’s Connect:👉 Subscribe:th-cam.com/channels/Fsw_y8cwA7UVXbIojXqS3A.html
//About me:Hvac Tech and Real Estate Agent , fighting to be the best , follow me on my adventure and lets find out the best of us //
Disclaimer:Links included in this description might be affiliate links. If you purchase a product or service with the links that I provide, I may receive a small commission. There is no additional charge to you! Thank you for supporting me so I can continue to provide you with free content each week!
มุมมอง: 248

วีดีโอ

How to change a Mitsubishi evaporator coil
มุมมอง 630ปีที่แล้ว
DISCLAIMER DO NOT TRY THIS AT HOME OR ON THE FIELD IF YOU ARE NOT AN HVAC PROFESSIONAL (th-cam.com/channels/Fsw_y8cwA7UVXbIojXqS3A.html ) //Recommended videos:▶️Compressor running backwards th-cam.com/video/dFMEC9xWwtk/w-d-xo.html ▶️ Hacked Customer filterth-cam.com/video/jSB3_nRA8YU/w-d-xo.html ▶️ ac compressor isn't starting ! th-cam.com/video/RMfP3fdBbg0/w-d-xo.html Check this products www.i...
How to check a capacitor using a formula
มุมมอง 663ปีที่แล้ว
DISCLAIMER DO NOT TRY THIS AT HOME OR ON THE FIELD IF YOU ARE NOT AN HVAC PROFESSIONAL (th-cam.com/channels/Fsw_y8cwA7UVXbIojXqS3A.html ) //Recommended videos:▶️Compressor running backwards th-cam.com/video/dFMEC9xWwtk/w-d-xo.html ▶️ Hacked Customer filterth-cam.com/video/jSB3_nRA8YU/w-d-xo.html ▶️ ac compressor isn't starting ! th-cam.com/video/RMfP3fdBbg0/w-d-xo.html Check this products www.i...
Ac Compresor getting iced up
มุมมอง 309ปีที่แล้ว
Music credits to: Powerful Trap Beat | Strong by Alex-Productions | onsound.eu/ Music promoted by www.chosic.com/free-music/all/ Creative Commons CC BY 3.0 creativecommons.org/licenses/by/3.0/ DISCLAIMER DO NOT TRY THIS AT HOME OR ON THE FIELD IF YOU ARE NOT AN HVAC PROFESSIONAL (th-cam.com/channels/Fsw_y8cwA7UVXbIojXqS3A.html ) //Recommended videos:▶️Compressor running backwards th-cam.com/vid...
How to change inverter board and thermistors on a Mitsubishi split unit
มุมมอง 11Kปีที่แล้ว
(th-cam.com/channels/Fsw_y8cwA7UVXbIojXqS3A.html ) //Recommended videos:▶️Compressor running backwards th-cam.com/video/dFMEC9xWwtk/w-d-xo.html ▶️ Hacked Customer filterth-cam.com/video/jSB3_nRA8YU/w-d-xo.html ▶️ ac compressor isn't starting ! th-cam.com/video/RMfP3fdBbg0/w-d-xo.html Check this products www.icybreeze.com?afmc=kt //Let’s Connect:👉 Subscribe:th-cam.com/channels/Fsw_y8cwA7UVXbIojX...
Lets OPEN this AC motor and see what FAILED
มุมมอง 149ปีที่แล้ว
(th-cam.com/channels/Fsw_y8cwA7UVXbIojXqS3A.html ) //Recommended videos:▶️Compressor running backwards th-cam.com/video/dFMEC9xWwtk/w-d-xo.html ▶️ Hacked Customer filterth-cam.com/video/jSB3_nRA8YU/w-d-xo.html ▶️ ac compressor isn't starting ! th-cam.com/video/RMfP3fdBbg0/w-d-xo.html Check this products www.icybreeze.com?afmc=kt //Let’s Connect:👉 Subscribe:th-cam.com/channels/Fsw_y8cwA7UVXbIojX...
Ac Electric Heater not working
มุมมอง 248ปีที่แล้ว
(th-cam.com/channels/Fsw_y8cwA7UVXbIojXqS3A.html ) //Recommended videos:▶️Compressor running backwards th-cam.com/video/dFMEC9xWwtk/w-d-xo.html ▶️ Hacked Customer filterth-cam.com/video/jSB3_nRA8YU/w-d-xo.html ▶️ ac compressor isn't starting ! th-cam.com/video/RMfP3fdBbg0/w-d-xo.html Check this products www.icybreeze.com?afmc=kt //Let’s Connect:👉 Subscribe:th-cam.com/channels/Fsw_y8cwA7UVXbIojX...
Unit running below freezing point , what can we do ?
มุมมอง 273ปีที่แล้ว
(th-cam.com/channels/Fsw_y8cwA7UVXbIojXqS3A.html ) //Recommended videos:▶️Compressor running backwards th-cam.com/video/dFMEC9xWwtk/w-d-xo.html ▶️ Hacked Customer filterth-cam.com/video/jSB3_nRA8YU/w-d-xo.html ▶️ ac compressor isn't starting ! th-cam.com/video/RMfP3fdBbg0/w-d-xo.html Check this products www.icybreeze.com?afmc=kt //Let’s Connect:👉 Subscribe:th-cam.com/channels/Fsw_y8cwA7UVXbIojX...
low voltage short , how to diagnose with your meter
มุมมอง 2452 ปีที่แล้ว
(th-cam.com/channels/Fsw_y8cwA7UVXbIojXqS3A.html ) //Recommended videos:▶️Compressor running backwards th-cam.com/video/dFMEC9xWwtk/w-d-xo.html ▶️ Hacked Customer filterth-cam.com/video/jSB3_nRA8YU/w-d-xo.html ▶️ ac compressor isn't starting ! th-cam.com/video/RMfP3fdBbg0/w-d-xo.html Check this products www.icybreeze.com?afmc=kt //Let’s Connect:👉 Subscribe:th-cam.com/channels/Fsw_y8cwA7UVXbIojX...
How to check if a lennox blower motor is bad
มุมมอง 3592 ปีที่แล้ว
(th-cam.com/channels/Fsw_y8cwA7UVXbIojXqS3A.html ) //Recommended videos:▶️Compressor running backwards th-cam.com/video/dFMEC9xWwtk/w-d-xo.html ▶️ Hacked Customer filterth-cam.com/video/jSB3_nRA8YU/w-d-xo.html ▶️ ac compressor isn't starting ! th-cam.com/video/RMfP3fdBbg0/w-d-xo.html Check this products www.icybreeze.com?afmc=kt //Let’s Connect:👉 Subscribe:th-cam.com/channels/Fsw_y8cwA7UVXbIojX...
Is the circuit board bad ?
มุมมอง 2182 ปีที่แล้ว
(th-cam.com/channels/Fsw_y8cwA7UVXbIojXqS3A.html ) //Recommended videos:▶️Compressor running backwards th-cam.com/video/dFMEC9xWwtk/w-d-xo.html ▶️ Hacked Customer filterth-cam.com/video/jSB3_nRA8YU/w-d-xo.html ▶️ ac compressor isn't starting ! th-cam.com/video/RMfP3fdBbg0/w-d-xo.html Check this products www.icybreeze.com?afmc=kt //Let’s Connect:👉 Subscribe:th-cam.com/channels/Fsw_y8cwA7UVXbIojX...
Compressor tripping the breaker
มุมมอง 3992 ปีที่แล้ว
(th-cam.com/channels/Fsw_y8cwA7UVXbIojXqS3A.html ) //Recommended videos:▶️Compressor running backwards th-cam.com/video/dFMEC9xWwtk/w-d-xo.html ▶️ Hacked Customer filterth-cam.com/video/jSB3_nRA8YU/w-d-xo.html ▶️ ac compressor isn't starting ! th-cam.com/video/RMfP3fdBbg0/w-d-xo.html Check this products www.icybreeze.com?afmc=kt //Let’s Connect:👉 Subscribe:th-cam.com/channels/Fsw_y8cwA7UVXbIojX...
Looking for a freon leak and doing a repair on it
มุมมอง 3232 ปีที่แล้ว
Looking for a freon leak and doing a repair on it
Compressor running backwards do to a power surge
มุมมอง 6K2 ปีที่แล้ว
Compressor running backwards do to a power surge
Filter installed incorrectly
มุมมอง 5392 ปีที่แล้ว
Filter installed incorrectly
Blower motor replacement
มุมมอง 5252 ปีที่แล้ว
Blower motor replacement
How to inject easy seal dye
มุมมอง 19K2 ปีที่แล้ว
How to inject easy seal dye
ac compressor isn't starting !
มุมมอง 57K2 ปีที่แล้ว
ac compressor isn't starting !
iso test
มุมมอง 2.4K2 ปีที่แล้ว
iso test
The ac air is not cold !!
มุมมอง 31K2 ปีที่แล้ว
The ac air is not cold !!
ac service call, hvac
มุมมอง 873 ปีที่แล้ว
ac service call, hvac
Best hvac hack
มุมมอง 6573 ปีที่แล้ว
Best hvac hack
How to clean ur ac drain line (hvac)
มุมมอง 1K3 ปีที่แล้ว
How to clean ur ac drain line (hvac)
hvac , How to check a contactor, plus video at the end !
มุมมอง 5503 ปีที่แล้ว
hvac , How to check a contactor, plus video at the end !

ความคิดเห็น

  • @thefreshride1510
    @thefreshride1510 หลายเดือนก่อน

    I have not installed a hard star capacitor.

  • @mortensommer8388
    @mortensommer8388 หลายเดือนก่อน

    I have problems with my ac. the red lamp in the outdoor unit flashes 6 times. I have debugged the inner part and the outer part. could my main pcb be faulty or could it be a sensor fault?

  • @moly1998
    @moly1998 หลายเดือนก่อน

    Dónde se encuentra el transistor de potencia

  • @SocratesDionisius
    @SocratesDionisius หลายเดือนก่อน

    What if we just put switch R & S on capacitor for a couple of second? Use capacitor that has more mikro farat?

  • @IdalmisDorta
    @IdalmisDorta หลายเดือนก่อน

    Good job

  • @IdalmisDorta
    @IdalmisDorta หลายเดือนก่อน

    Good job!!!!

  • @IdalmisDorta
    @IdalmisDorta หลายเดือนก่อน

    👍

  • @IdalmisDorta
    @IdalmisDorta หลายเดือนก่อน

    Thanks!!!

  • @IdalmisDorta
    @IdalmisDorta หลายเดือนก่อน

    Very good. Thanks

  • @IdalmisDorta
    @IdalmisDorta หลายเดือนก่อน

    Good job

  • @IdalmisDorta
    @IdalmisDorta หลายเดือนก่อน

    Thanks

  • @IdalmisDorta
    @IdalmisDorta หลายเดือนก่อน

    Thanks!!!

  • @IdalmisDorta
    @IdalmisDorta หลายเดือนก่อน

    Thanks!!!!

  • @IdalmisDorta
    @IdalmisDorta หลายเดือนก่อน

    👍👍👍

  • @IdalmisDorta
    @IdalmisDorta หลายเดือนก่อน

    Thanks😊

  • @georgepetrillo7316
    @georgepetrillo7316 3 หลายเดือนก่อน

    Excellant video. My issue is a little different. Had a power outage today. Power came back on and then it went off again. When the power came back on I noticed that the a/c was not blowing cold. The a/c breaker switch was tripped. Reset the breaker, heard a buzz, breaker tripped. Reset the breaker again, heard a buzz, breaker tripped again. Went to the compressor outside and the fan was not running. However, the fan spins freely by hand. Now I have the breaker off till I get this sorted out out. Don't know if its a bad capacitor , start switch or contactor.

    • @coldflashac6443
      @coldflashac6443 3 หลายเดือนก่อน

      The buzz is the compressor trying to start or is locked on lock rotor amps causing the wire to over heat and tripping your breaker this video was the same issue you could also have a bad capacitor if is an older unit recommend having a start kit capacitor , please call a professional

    • @georgepetrillo7316
      @georgepetrillo7316 3 หลายเดือนก่อน

      @@coldflashac6443 Had one a/c company come over to trouble shoot. Found it was a bad compressor. Didn't want to get just one diagnosis so I called another a/c company to do the same diagnosis. 2nd person came over a few hours after the first person. The second a/c tech did some trouble shooting and found the same thing. I didn't mention that I already had a diagnosis because I wanted to the 2nd person to fully trouble shoot the problem.

  • @6809darton
    @6809darton 3 หลายเดือนก่อน

    pls help, how do i know which ac hard start kit for my residential ac my is lennox 5 ton

    • @coldflashac6443
      @coldflashac6443 3 หลายเดือนก่อน

      CSRU2 CSR-U2 AC Hard Start Kit 3.5 to 5 tons

    • @6809darton
      @6809darton 3 หลายเดือนก่อน

      @@coldflashac6443thank you

  • @realSamAndrew
    @realSamAndrew 4 หลายเดือนก่อน

    Is the system running while you inject the dye?

    • @alexrolon3505
      @alexrolon3505 4 หลายเดือนก่อน

      Yea the system has to be running in order to inject the dye

  • @malcolmshvac6692
    @malcolmshvac6692 4 หลายเดือนก่อน

    only good for the dye never gonna work on a liquid line sealing

  • @SoCalRobots
    @SoCalRobots 4 หลายเดือนก่อน

    This is exactly what I was thinking of doing and now you've confirmed it. I'll just hit mine to start every time lol! better than spending $11,000 for now

  • @Menu2Sports
    @Menu2Sports 4 หลายเดือนก่อน

    Great info, fixed my own for $30 as a result.

  • @LyonsLeo
    @LyonsLeo 4 หลายเดือนก่อน

    Super helpful as a mime, but don't be shy. Some narrative would bring this video to five stars.

    • @coldflashac6443
      @coldflashac6443 4 หลายเดือนก่อน

      Thanks for the comment 5 stars already ✌️

  • @susanazapata9205
    @susanazapata9205 4 หลายเดือนก่อน

    Im tired this darn machine a 1 1/2 qn 2 service calls they supposed to have filled n 24 hr later no cold air secon tine refill an lasted 48hrs the machine doesn’t stop n know not blowing air have been looking for a leak n nothing, what else can it be

    • @coldflashac6443
      @coldflashac6443 4 หลายเดือนก่อน

      If is loosing freon it has a leak if is hard to find looks like you need an isolation test meaning pressure all the components indoor unit line set and outdoor unit come back in 2 or 3 days and see if it lost nitrogen pressure, this is not an advice contact a licensed professional thanks

  • @DJV94022
    @DJV94022 4 หลายเดือนก่อน

    Has anyone else delt with the bad batch of lennox air handlers with stuck txvs? Well tapping it with the hammer gets em going. Seems like if you tap a txv, Compressors and reversing valve does temperary fixes. I know the txv being new itll work for ever The reversing valve 50/50 chance itll stay good or go out bad in the next heat/cool switch But the compressor tells you itll last another 6 months or so

    • @coldflashac6443
      @coldflashac6443 4 หลายเดือนก่อน

      Yea the trick of the tapping magic lol , we changed this compressor already they waited 5 months

    • @coldflashac6443
      @coldflashac6443 4 หลายเดือนก่อน

      A lot of techs braze with out nitrogen also they don’t remove the txv bulb while brazing thats why the fail

  • @markanders250
    @markanders250 5 หลายเดือนก่อน

    Goodmans, that explains it all.

    • @coldflashac6443
      @coldflashac6443 5 หลายเดือนก่อน

      Yup have you run into the new amanas and daikin ?

  • @Jimbo90331
    @Jimbo90331 5 หลายเดือนก่อน

    I’ve probably put in over 100 or more of theses and only had it stop maybe 1-2 leaks

  • @DejaePacmann001-fe8em
    @DejaePacmann001-fe8em 5 หลายเดือนก่อน

    Do you shut the unit off first or leave it running?

    • @coldflashac6443
      @coldflashac6443 5 หลายเดือนก่อน

      Leave it running so the compressor can suck the dye

    • @DejaePacmann001-fe8em
      @DejaePacmann001-fe8em 5 หลายเดือนก่อน

      @@coldflashac6443 Thanx!

  • @jimmydouglas5283
    @jimmydouglas5283 7 หลายเดือนก่อน

    Is it possible to find the black mounting piece by itself?

  • @vishalkakade8710
    @vishalkakade8710 7 หลายเดือนก่อน

    Pries kya hai

  • @grayson5933
    @grayson5933 8 หลายเดือนก่อน

    ☀️ *PromoSM*

  • @gabrielarigali2896
    @gabrielarigali2896 9 หลายเดือนก่อน

    👏🏻👏🏻

  • @jordanhenshaw
    @jordanhenshaw 9 หลายเดือนก่อน

    High superheat low subcool? Seems like possible low charge contributed to floodback and you had flooded starts or slugging which may have deprived comp of oil, contributing to LRA. Verify proper cap rating is Copeland spec (I've often found 30's on comps meant for 35's and 35's on comps meant for 30's.) and make sure the dang superheat and subcool numbers are definitely not indicative of low charge (as pictured in the video, they are). The unstable amp draw on compressor on startup may have been oil returning? Not sure though. If compressor actually got replaced (it shouldn't based just on the info in this video), definitely dump the oil and then drill out the evap if oil level turns out to be super low.

  • @Kuntmala
    @Kuntmala ปีที่แล้ว

    This is extremely helpful, I was trying to figure out how to read error codes, mine is exactly like this. My AC works fine for days, then shuts off, indoor light blinks constantly. Tech came out first time added a little bit of refrigerant and dye and said to call back if it did it again. When I do the error retrieval on the indoor unit, it is long light then 1 blink/beep; set to 77 and went to the outdoor unit but didn't have enough time to figure it out yesterday. It will run again if I press on/off. What would be your first thing to check? I guess I need to figure out what the outdoor unit is saying now that I can see how to get to the board.

    • @coldflashac6443
      @coldflashac6443 ปีที่แล้ว

      Look up online mitsubishi light troubleshooting manual , if is a continuous blinking could be the board but i will recommend you a professional

  • @micro963
    @micro963 ปีที่แล้ว

    Thank you for sharing. Having the same problem. Service company recommended to have a surge protector install for the unit. Do you think that would help? Thank you

    • @coldflashac6443
      @coldflashac6443 ปีที่แล้ว

      Surge protector is always good to have reach out to your electrical company and see if the offer a surge protector at the meter, but you probably need a time delay on break , so if power goes out the outdoor unit will wait 5 minutes until it start back up you can also add that feature on the thermostat depending on the thermostat

    • @micro963
      @micro963 ปีที่แล้ว

      Thank you very much, do you know what kind of thermostat would have that feature to wait five minutes before turn back the unit on again?

  • @trisoil
    @trisoil ปีที่แล้ว

    Thanks for your video. It really helped me.

  • @rodolfomanuel797
    @rodolfomanuel797 ปีที่แล้ว

    Very straight forward buddy thank you!

  • @xcbcm
    @xcbcm ปีที่แล้ว

    Found my unit running backwards after noticing the house was not cooling very well. Condenser fan running backwards and a lot of heat coming out of the unit. Shut it down and did a restart and everything was ok. After a storm same thing happened. I replaced the capacitor, but the unit did it again. The unit is not a heat pump.

    • @coldflashac6443
      @coldflashac6443 ปีที่แล้ว

      Looks like you need a time delay switch on the out door unit or check if your thermostat time delay is on

  • @g.kthakur6062
    @g.kthakur6062 ปีที่แล้ว

    यह तो एक नॉर्मल मैकेनिक भी फिट कर सकता है पीसीबी क्यों चेंज की वह बताओ

  • @jackmurphy9371
    @jackmurphy9371 ปีที่แล้ว

    Your explanation of why it is running backwards, doesn’t make sense. I have seen them run backwards after power surge. The solution is to change the position of L1 and L2 at the input side of the contactor. I have only seen this anomaly once after a power surge.

    • @coldflashac6443
      @coldflashac6443 ปีที่แล้ว

      Changing legs wont do anything only on 3 phase motors

    • @coldflashac6443
      @coldflashac6443 ปีที่แล้ว

      Go to your ac unit and trip the water safety switch and let go after half a second and let me know what your compressor does if you dont have a timer delay switch or your thermostat dont have a time delay

  • @Hikesay
    @Hikesay ปีที่แล้ว

    hat was this? Initially, you said the capacitor is completely dead, and then after a min you said capacitor is working good.

  • @znrctrnn
    @znrctrnn ปีที่แล้ว

    How old was the unit? Was it worth ordering the compressor?

  • @jerrylockhart3069
    @jerrylockhart3069 ปีที่แล้ว

    This shi t doesn’t work. What a scam.😮😅🥵🐵🙉🙈

  • @jlgmdano
    @jlgmdano ปีที่แล้ว

    Where can I order a compressor? Or better yet, where do I check for warranty?

  • @markrogge3098
    @markrogge3098 ปีที่แล้ว

    Is there a technical name for why the compressor reverses

    • @coldflashac6443
      @coldflashac6443 ปีที่แล้ว

      For the compressor to stop runs backwards so if you apply power while is stopping it will run backwards

    • @markrogge3098
      @markrogge3098 ปีที่แล้ว

      @coldflashac6443 would a hardware delay mounted on the ubit have 100% prevented this? My thermostat has an electronic delay but it didn't help.

  • @briley337
    @briley337 ปีที่แล้ว

    This video saved me hundreds of dollars. Thank you so much!

  • @fldave612
    @fldave612 ปีที่แล้ว

    29.4 is outside of limits on the herm, but not low enough to keep it from starting.

  • @james10739
    @james10739 ปีที่แล้ว

    Thats a cool little thing

  • @james10739
    @james10739 ปีที่แล้ว

    They way those compressors are inside the case I'm not sure tapping does much and honestly if it does I doubt a rubber mallet would do it and you are not hitting a new or good compressor

  • @butlerstouchHVAC
    @butlerstouchHVAC ปีที่แล้ว

    what you record with?

  • @butlerstouchHVAC
    @butlerstouchHVAC ปีที่แล้ว

    great diagnosis