- 60
- 318 059
BOILER OPERATION ENGINEER & TURBINE
India
เข้าร่วมเมื่อ 10 ม.ค. 2020
BEST APPROACH TO KNOW ABOUT BOILER AND TURBINE.IN THIS CHANNEL YOU WILL GET BEST UNDERSTANDING BETWEEN ALL TYPES OF BOILER AND TURBINE WITH SMALLEST DETAILS IN BREAF.
DM PLANT & RO PLANT INTERVIEW QUESTIONS || BOE INTERVIEW QUESTIONS || BOE PREPARATION
Hi friends you all will find me on following link for any query related to BOE and BOILER ATTENDANT preparation and also Turbine related queries you can also reach me at following platform TELEGRAM t.me/hokbsjd FACEBOOK PAGE groups/386300106143445/?ref=share INSTAGRAM ajitpandey4211
มุมมอง: 7 166
วีดีโอ
B.O.E. INTERVIEW // FUEL AND COMBUSTION // PROPERTIES OF STEAM
มุมมอง 3.8K2 ปีที่แล้ว
Hi friends you all will find me on following link for any query related to BOE and BOILER ATTENDANT preparation and also Turbine related queries you can also reach me at following platform TELEGRAM t.me/hokbsjd FACEBOOK PAGE groups/386300106143445/?ref=share INSTAGRAM ajitpandey4211
B.O.E. INTERVIEW PREPRATION //QUESTIONS FROM A R MALIC BOOK // FUNDAMENTALS // HEAT TRANSFER
มุมมอง 2.4K2 ปีที่แล้ว
Hi friends you all will find me on following link for any query related to BOE and BOILER ATTENDANT preparation and also Turbine related queries you can also reach me at following platform TELEGRAM t.me/hokbsjd FACEBOOK PAGE groups/386300106143445/?ref=share INSTAGRAM ajitpandey4211
SACRIFICIAL ANODE // GALVANIC CORROSION IN CONDENSER // CORROSION PREVENTION
มุมมอง 2.3K2 ปีที่แล้ว
Hi friends you all will find me on following link for any query related to BOE and BOILER ATTENDANT preparation and also Turbine related queries you can also reach me at following platform TELEGRAM t.me/hokbsjd FACEBOOK PAGE groups/386300106143445/?ref=share INSTAGRAM ajitpandey4211
SURFACE CONDENSER || VACCUM FUNDAMENTAL || DIRECTION OF COOLING WATER FLOW
มุมมอง 1.3K2 ปีที่แล้ว
Hi friends you all will find me on following link for any query related to BOE and BOILER ATTENDANT preparation and also Turbine related queries you can also reach me at following platform TELEGRAM t.me/hokbsjd FACEBOOK PAGE groups/386300106143445/?ref=share INSTAGRAM ajitpandey4211
CONCEPT OF STEAM CONDENSER || TURBINE WITH & WITHOUT CONDENSER || TURBINE WORK BENIFIT BY CONDENSER
มุมมอง 1.2K2 ปีที่แล้ว
WORK BENIFITS OF TURBINE DIE TO CONDENSER || TURBINE WITHOUT CONDENSER || WHAT HAPPENED IF CONDENSER REMOVE Hi friends you all will find me on following link for any query related to BOE and BOILER ATTENDANT preparation and also Turbine related queries you can also reach me at following platform TELEGRAM t.me/hokbsjd FACEBOOK PAGE groups/386300106143445/?ref=share INSTAGRAM ajitpan...
CENTRAL BOE 2021 SOLVED NUMERICAL || BOILER EFFICIENCY || [ Take 8*H2 instead of 9*H2 in TA ]
มุมมอง 1.8K2 ปีที่แล้ว
Hi friends you all will find me on following link for any query related to BOE and BOILER ATTENDANT preparation and also Turbine related queries you can also reach me at following platform TELEGRAM t.me/hokbsjd FACEBOOK PAGE groups/386300106143445/?ref=share INSTAGRAM ajitpandey4211
INDIAN BOILER REGULATIONS || CETRAL BOILER OPERATION ENGINEERING || BOE SPECIAL
มุมมอง 6K2 ปีที่แล้ว
INDIAN BOILER REGULATIONS || CETRAL BOILER OPERATION ENGINEERING || BOE SPECIAL
GUJARAT BOE 2017 NUMERICAL || CONDENSATE || RETURN CONDENSATE
มุมมอง 1.7K2 ปีที่แล้ว
GUJARAT BOE 2017 NUMERICAL || CONDENSATE || RETURN CONDENSATE
GUJRAT BOE 2017 NUMERICAL || COMBUSTION || EXCESS AIR || ACTUAL AIR SUPPLY
มุมมอง 1.1K2 ปีที่แล้ว
GUJRAT BOE 2017 NUMERICAL || COMBUSTION || EXCESS AIR || ACTUAL AIR SUPPLY
GUJRAT BOE 2017 20 MERK NUMERICAL || BOILER EFFICIENCY CALCULATION BY INDIRECT METHOD
มุมมอง 1.3K2 ปีที่แล้ว
GUJRAT BOE 2017 20 MERK NUMERICAL || BOILER EFFICIENCY CALCULATION BY INDIRECT METHOD
HOW TO FILL CENTRAL BOE FORM ONLINE // LAST DATE TO FILL FORM 25 NOVEMBER
มุมมอง 2K2 ปีที่แล้ว
HOW TO FILL CENTRAL BOE FORM ONLINE // LAST DATE TO FILL FORM 25 NOVEMBER
STEAM SOOT BLOWER // BOE QUESTION // LRSB //SRSB //WALL BLOWER
มุมมอง 6K2 ปีที่แล้ว
STEAM SOOT BLOWER // BOE QUESTION // LRSB //SRSB //WALL BLOWER
CHIMNEY DRAUGHT // CHIMNEY HEIGHT // CHIMNEY DIAMETER // GUJARAT & KERLA BOE NUMERICALS
มุมมอง 6K2 ปีที่แล้ว
CHIMNEY DRAUGHT // CHIMNEY HEIGHT // CHIMNEY DIAMETER // GUJARAT & KERLA BOE NUMERICALS
HIGH STEAM LOW WATER SAFETY VALVE // PARTS AND DISCRIPTION OF SV // BOE PREPRATION
มุมมอง 1.8K2 ปีที่แล้ว
HIGH STEAM LOW WATER SAFETY VALVE // PARTS AND DISCRIPTION OF SV // BOE PREPRATION
KERLA BOE 2018 PAPER # 2 // DISADVANTAGE OF PULVERIZED COAL FIRING // WHY WE GIVE BLODOWN IN BOILER
มุมมอง 1.1K2 ปีที่แล้ว
KERLA BOE 2018 PAPER # 2 // DISADVANTAGE OF PULVERIZED COAL FIRING // WHY WE GIVE BLODOWN IN BOILER
SPRING LOADED SAFETY VALVE // SETTING OF SAFETY VALVE //BLOWDOWN ADJUSTMENT OF SAFETY VALVE // B.O.E
มุมมอง 7K3 ปีที่แล้ว
SPRING LOADED SAFETY VALVE // SETTING OF SAFETY VALVE //BLOWDOWN ADJUSTMENT OF SAFETY VALVE // B.O.E
KERALA B.O.E. PAPER 2018 / PAPER # 1 PART - B / NUMERICALS WITH THEORY EXPLANATION
มุมมอง 1.7K3 ปีที่แล้ว
KERALA B.O.E. PAPER 2018 / PAPER # 1 PART - B / NUMERICALS WITH THEORY EXPLANATION
KERALA B.O.E. PAPER SOLUTION / 2018 KERALA B.O.E. PAPER / PAPER # 1
มุมมอง 3K3 ปีที่แล้ว
KERALA B.O.E. PAPER SOLUTION / 2018 KERALA B.O.E. PAPER / PAPER # 1
[ BOE 2021 ] || FATIGUE CORROSION || STRESS CORROSION CRACKING || BOILER TUBE FAILURE
มุมมอง 3.7K3 ปีที่แล้ว
[ BOE 2021 ] || FATIGUE CORROSION || STRESS CORROSION CRACKING || BOILER TUBE FAILURE
[ BOE 2021 ] || HYDROGEN DAMAGE || OXYGEN CORROSION || BOILER TUBE LEAKAGE || POWER PLANT
มุมมอง 4.8K3 ปีที่แล้ว
[ BOE 2021 ] || HYDROGEN DAMAGE || OXYGEN CORROSION || BOILER TUBE LEAKAGE || POWER PLANT
[ BOE 2021 ] || LONG TERM AND SHORT TERM OVERHEATING || POWER PLANT || BOILER TUBE FAILURE
มุมมอง 7K3 ปีที่แล้ว
[ BOE 2021 ] || LONG TERM AND SHORT TERM OVERHEATING || POWER PLANT || BOILER TUBE FAILURE
[BOE 2021] || PERFORMANCE CURVE OF SUPERHEATERS || SUPERHEATERS METAL TEMPERATURE AS PER IBR
มุมมอง 3.5K3 ปีที่แล้ว
[BOE 2021] || PERFORMANCE CURVE OF SUPERHEATERS || SUPERHEATERS METAL TEMPERATURE AS PER IBR
SUPERHEATERS || PLATEN || CEILING | RADIANT | CONVECTIVE | INLINE | STAGGERED | PARALLEL |CROSS FOW
มุมมอง 4.2K3 ปีที่แล้ว
SUPERHEATERS || PLATEN || CEILING | RADIANT | CONVECTIVE | INLINE | STAGGERED | PARALLEL |CROSS FOW
[ BOE 2021 ] / THROTTLING PROCESS / ISENTHALPIC PROCESS / CHHATTISSGARH BOE
มุมมอง 1.2K3 ปีที่แล้ว
[ BOE 2021 ] / THROTTLING PROCESS / ISENTHALPIC PROCESS / CHHATTISSGARH BOE
[ BOE 2021 ] / CHHATTISGARH BOE / 2017 PAPER NUMERICAL / QUANTITY OF LIME AND SODA CALCULATION
มุมมอง 8443 ปีที่แล้ว
[ BOE 2021 ] / CHHATTISGARH BOE / 2017 PAPER NUMERICAL / QUANTITY OF LIME AND SODA CALCULATION
[ BOE 2021 ] / LAP AND BUTT WELD JOINTS / NUMERICAL OF WELD JOINTS/ CHHATTISHGARH BOE 2021
มุมมอง 1.8K3 ปีที่แล้ว
[ BOE 2021 ] / LAP AND BUTT WELD JOINTS / NUMERICAL OF WELD JOINTS/ CHHATTISHGARH BOE 2021
[ BOE 2021 ] || STRENGTH OF MATERIAL || TARGET CHHATTISGARH BOE || CG 2017 PAPER
มุมมอง 3.4K3 ปีที่แล้ว
[ BOE 2021 ] || STRENGTH OF MATERIAL || TARGET CHHATTISGARH BOE || CG 2017 PAPER
[ BOE 2021 ] //CHHATTISGARH BOE // 2017 PAPER NUMERICALS
มุมมอง 2.3K3 ปีที่แล้ว
[ BOE 2021 ] //CHHATTISGARH BOE // 2017 PAPER NUMERICALS
[BOE 2021] /PRESSURE CONVERSION TIPS/CONFIRM SCORE/ CHHATISHGARH BOE // CG BOE PREPRATION
มุมมอง 3.3K3 ปีที่แล้ว
[BOE 2021] /PRESSURE CONVERSION TIPS/CONFIRM SCORE/ CHHATISHGARH BOE // CG BOE PREPRATION
Sir aajkal kaha ho ap
Sir there is a small mistake at 20.35 that is the minimum size of the steam pipe is 25.4mm(1inch)
How to contact with u to clearfy some doubt
What is your facebook id
Ok
Sir, how to calculate how much steam is used during soot blowing
Matarial me sab se best grade koi si hoti A,B,C me
Sir,fruitful information.thank you.but sir,voice is getting like hall background.please correct it.
Thank you sir
👍
Thanks sir 🙏, beautiful, beautifully explained sir.
Servo motor keise operate hota hai? Agar i to h mai 4 ma hai to 1.5 kg PR keise build up hota hai?
Thanks,sir
Thanks for improving our knowledge
if you use better mic, your channel will grow faster.
better mic use kar liya karo.... sound sahi se nahi ataa
Please say about seal,s there use and cause of lkg
What is the ratio of fluegas ,air
Please mention about Seal lkg reason .... Recognition.. And prevention
Brother heartily thank please send 210MW kWH turbine drawing
What is 0.9 factor please explain
What are the register to be maintain at Boiler plant.Please let me know
Respected sir... Bed coil, water wall or superheater mein kaun kaun sa heat transfer hota h.. Kis mein kaun sa heat transfer hota h? Plzz explain
Upload the video briffly Steam Control valves lift checking through servo/ pilot valves
Boiler efficiency and boiler capacit, boiler heat rate
Steam fuel ratio pr video upload kr digiye sir
boiler operation engineer ke liye ab new form kab dalega ...2024 ke liye
We are using SS316L material which is handling 310 C temp steam and we are facing caustic CSS failures frequently what is the remedy?
Sir what the difference between gague glass and hydrastep
Thanks for explaining about the IBR. Could you please let me know what is the frequency of UT & ET test of a pressure vessel?
Vortex Cylinder Material ?
Sir, May i get in touch with you for some clarification. I will not disturb you promise just for knowledge
Fecl3 coagulatnt agent hum kyun use karty Hain jab ky alum hai feso4 bhi hai
nice🙏🙏
Sir im working in hydropwerplant can uh explain the governinv mechanism in hydropowerplant how governor kept constant rpm at varying load condition?
sir height of chimney ke bare me calculation ka video bnae plz
Thank you so much sir✨
Sir, please let me know which material used in making of resins?
Experience letter kab tak valid hota hai
sir, After wet preservation of boiler. can i remove all the chemical water before start the boiler. or drain water upto 50% of steam drum then start the boiler. please confirm which on is good.
Sir WAC, SAC AND SBA, WBA, RESIN ME KYA FARAK HAI
Condenser ko full izzat
At video time 18:25 me aapne mass flow rate 1800kg/t ko 1800/3600=7kg/sec kaise aaya explain kriye jabki wo 0.5kg/sec aayega
Sir please make full details of Ro & uf plant
Please continue your classes
Thank you sir
Hi. Can anyone tell me that if GAD is approved by IBR inspector, and quantity mentioned in GAD is only one. Than can manufacturer make more than one component based on that same IBR approved GAD? Please let me know. It would be very helpful for me.
Thankusir
Many thanks for post. 🎉 in numerical-2, do we need to consider mass flow rate of Flue gas instead of coal glow rate whe calculating chimney dia. since flue gas produced per kg of coal is 14 ??
How much capacity thermic fluid is required permission for installation ?