Peak Fractionation Instruction
Here we discuss the Peal Fractionation instruction in Unicorn for use on AKTA chromatography systems like the Avant, Go or Pure. The Peak Fractionation instruction is used in the manual and method modules for some tight fraction action! This instruction will allow you to save tons of tubes as you crank out run after run.
For further reading generally on how to use the AKTA Avant see: cdn.cytivalifesciences.com/api/public/content/digi-10624-original
Reach me at my Linkedin page www.linkedin.com/in/chad-blamey-ph-d-649a336/
Music:
Midnight by Massobeats - freetouse.com/music/massobeats/midnightChamomile by Massobeats - freetouse.com/music/massobeats/chamomile
Lush by Massobeats - freetouse.com/music/massobeats/lush
This music is not mine it is used under a creative commons license. Thanks for letting me use your music I really like it!
มุมมอง: 2

วีดีโอ

Gradient Instruction In Unicorn for AKTA chromatography systems
มุมมอง 3219 ชั่วโมงที่ผ่านมา
Here we discuss the Gradient Instruction in Unicorn for use on AKTA chromatography systems like the Avant, Go or Pure. The Gradient instruction is used in the manual and method modules to control the ratio of pump A and pump B. When you are working with the gradient instruction in the method editor be sure to pay careful attention to the breakpoints as these can change in two places at once. Fo...
The Secrets Of The Flow Instruction
มุมมอง 38หลายเดือนก่อน
This is a video about instructions in Unicorn. My goal is to eventually describe how to use (almost) every instruction in Unicorn for use on the AKTA Avant, Go and Pilot. We'll see how far I get. Covered here is the System Flow instruction. For further reading generally on how to use the AKTA Avant see: cdn.cytivalifesciences.com/api/public/content/digi-10624-original Reach me at my Linkedin pa...
Packing A HIC Tricorn Column
มุมมอง 1472 หลายเดือนก่อน
Here we pack a column that is 5 mm wide, so tiny, to a height of 8 cm for chromatography purification. We use a Tricorn column from Cytiva with Hydrophobic Interaction Chromatography (HIC) resin (or media). We use Phenyl HP to pack this column. You can use this technique to pack just about any Tricorn column. You could use this technique to pack any flavor of column like IEX, affinity, desaltin...
Packing The XK Column For Chromatography
มุมมอง 3902 หลายเดือนก่อน
Hey so here we pack an 8 cm XK column from Cytiva with Hydrophobic Interaction Chromatography (HIC) resin (or media). We use Phenyl HP to pack this column. You can use this technique to pack just about any XK column, large or small. You could use it to pack an IEX, affinity, desalting or SEC column as well. I do not represent Cytiva & this is not a paid promotion. For some moderately unhelpful ...
Woohoo! Changing The Sounds Your AKTA Avant Makes With Unicorn Software.
มุมมอง 813 หลายเดือนก่อน
Here we totally nerd out and have some 'fun' with Unicorn by changing the sounds your system makes. This works with any AKTA chromatography system with Unicorn control, the Avant, Pure, Go, Pilot and Process just for starters. I made my system say Woohoo like Homer Simpson. Just trying to have some fun and lighten the mood maybe. For further reading generally on how to use the AKTA Avant see: c...
How To Make A Preset SEC Method On The AKTA Go
มุมมอง 1663 หลายเดือนก่อน
In this introductory video we go over EVERY step in how to make a Size Exclusion Chromatography (SEC) method for the AKTA Go using Unicorn software from Cytiva. We also set up the system and briefly review the results. I don't represent Cytiva and I am not (nor have I ever been) paid by Cytiva. I'm just super into chromatography. How to make a custom column in Unicorn. th-cam.com/video/qYlFHvSk...
A Basic Intro To Understanding Chromatography Results Collected With The AKTA Chromatography System
มุมมอง 2064 หลายเดือนก่อน
In this introductory video I show you how to view and understand your chromatography results. It's super basic. I used Unicorn software that runs the AKTA chromatography system suits like the Avant, Pure, Pilot and Go. Here I use an affinity purification I did with Protein A resin/media. Please leave a comment below and good luck with your purifications! Reach me at my Linkedin page www.linkedi...
The Base Matrix Of Your Chromatography Resin Is Really Important.
มุมมอง 635 หลายเดือนก่อน
Here we talk about how the base matrix of chromatography resin (media/gel) affects performance of your runs. I mostly make videos about using the AKTA Chromatography systems like the Avant, Pure, Pilot and Go with Unicorn Software from Cytiva for preparative purification. (I don't work for Cytiva and I'm not paid by them either.) This talk also applies to some other kinds of chromatography like...
Replacing The Inline Filter Of An AKTA Avant Chromatography System.
มุมมอง 2615 หลายเดือนก่อน
Wait the AKTA Avant has an inline filter? The inline filter often gets dirty or contaminated which can lead to high back pressure of contamination of your purified samples. Here I will show you how to replace the inline filter, it is easy and takes about 2 minutes. But honestly you don't even need the filter. I took my filter out and never looked back. I always filter my cell harvests and usual...
MultiDimensional Chromatography Setup
มุมมอง 707 หลายเดือนก่อน
In this video we learn how setup for the multidimensional chromatography method we made a little while back using a desalting column and some anion exchange columns on an AKTA Avant. This method allows us to test many different conditions using multiple buffers at the same time! For example the sample can be in high salt with low pH conditions and the method will still work. This is an 'advance...
An Example of Multi Dimensional Chromatography: Desalt and Ion Exchange
มุมมอง 1008 หลายเดือนก่อน
In this video we learn how to do multi dimensional chromatography using a desalting column and some anion exchange columns on an AKTA Avant. To start we are building on an a resin selection project we did earlier see below. This method will allow us to test many different conditions using multiple buffers at the same time! For example the sample can be in high salt with low pH conditions and th...
Creating Reminders In Unicorn Chromatography Software.
มุมมอง 418 หลายเดือนก่อน
In this quick video I'll show you how to set up a reminder for an AKTA Avant, or Pure or any other system that is controlled by Unicorn Software. This can be convenient for reminding you when to do periodic maintenance with your system, or just to tell you to take a minute for yourself to eat lunch. I hope you enjoy. I thought this content would be helpful because I haven't found anything about...
Changing The Settings On The AKTA Avant in Unicorn. Most Helpful Thing Ever!
มุมมอง 1489 หลายเดือนก่อน
In this video we discuss how to change the System Settings in the Control Module of Unicorn Chromatography software. We use an AKTA Avant as an example but this could be applied to any system like the AKTA Pure, Pilot or Go. Here we change the defaults of the Avant's fraction collector, pressure limit, and pump wash volume. Here is an OK discussion on changing system settings from the Unicorn 6...
How to Fix a Broken Fraction Collector Tube on the AKTA Avant Chromatography System
มุมมอง 2099 หลายเดือนก่อน
This last week I had fraction collector tubes break on me on two separate systems. It is annoying to wait for a service call especially when a new tube can be swapped out in less than 5 minutes. Here is how I did the change. I am not endorsed by or paid by Cytiva. The opinions expressed here are my own. The part number references in the video are subject to change, I am only offering them as a ...
How Unlock Unicorn Method or Result Files For All Chromatography Systems.
มุมมอง 28010 หลายเดือนก่อน
How Unlock Unicorn Method or Result Files For All Chromatography Systems.
Setup For Selection of Ion Exchange Medias Using A Unicorn Method on the AKTA Avant.
มุมมอง 11910 หลายเดือนก่อน
Setup For Selection of Ion Exchange Medias Using A Unicorn Method on the AKTA Avant.
Look At All Those Zeros! Reading Unicorn Language with AKTA Chromatography Systems
มุมมอง 22411 หลายเดือนก่อน
Look At All Those Zeros! Reading Unicorn Language with AKTA Chromatography Systems
Best and Worst About the AKTA Avant (in my opinion)
มุมมอง 9311 หลายเดือนก่อน
Best and Worst About the AKTA Avant (in my opinion)
Selection of Ion Exchange Medias Using A Unicorn Method on the AKTA Avant.
มุมมอง 214ปีที่แล้ว
Selection of Ion Exchange Medias Using A Unicorn Method on the AKTA Avant.
Setting Up a Custom Affinity Method Using Scouting for the AKTA Avant Chromatography System.
มุมมอง 257ปีที่แล้ว
Setting Up a Custom Affinity Method Using Scouting for the AKTA Avant Chromatography System.
Testing a Unicorn Method on the AKTA Avant Chromatography System
มุมมอง 168ปีที่แล้ว
Testing a Unicorn Method on the AKTA Avant Chromatography System
Writing a Custom Affinity Method Using Scouting for the AKTA Avant Chromatography System.
มุมมอง 376ปีที่แล้ว
Writing a Custom Affinity Method Using Scouting for the AKTA Avant Chromatography System.
Making a Custom Column in Unicorn Chromatography Software for the AKTA Avant
มุมมอง 113ปีที่แล้ว
Making a Custom Column in Unicorn Chromatography Software for the AKTA Avant
Break Points and Timing In Unicorn on AKTA Avant
มุมมอง 281ปีที่แล้ว
Break Points and Timing In Unicorn on AKTA Avant
AKTA Avant Flow Path
มุมมอง 631ปีที่แล้ว
AKTA Avant Flow Path
Understanding blocks in Unicorn software for AKTA Avant
มุมมอง 849ปีที่แล้ว
Understanding blocks in Unicorn software for AKTA Avant
Adding A Variable In Unicorn Chromatography Software for AKTA Avant.
มุมมอง 201ปีที่แล้ว
Adding A Variable In Unicorn Chromatography Software for AKTA Avant.
Adding a block in Unicorn chromatography software for AKTA Avant
มุมมอง 143ปีที่แล้ว
Adding a block in Unicorn chromatography software for AKTA Avant
Loading a super loop #shorts
มุมมอง 543ปีที่แล้ว
Loading a super loop #shorts

ความคิดเห็น

  • @giantbird
    @giantbird 22 ชั่วโมงที่ผ่านมา

    THANK YOU MY FRIEND .

    • @UnicornStuff
      @UnicornStuff 7 ชั่วโมงที่ผ่านมา

      I'm glad you liked this video! I worked really hard on it and to find that someone found it useful is great!

  • @giantbird
    @giantbird 23 ชั่วโมงที่ผ่านมา

    Thank you so much. do you have two step purification, protein A and desalt column training one? usually I need buffer exchange after purification to remove the tris component which was used neutralized the elution buffer. thanks.

  • @giantbird
    @giantbird 23 ชั่วโมงที่ผ่านมา

    Do you know how much about Akta Training? I am looking for a protein related jobs now...

  • @giantbird
    @giantbird 23 ชั่วโมงที่ผ่านมา

    thank you for you terrific work!

  • @giantbird
    @giantbird 23 ชั่วโมงที่ผ่านมา

    thank you for you method!

  • @johnburd3180
    @johnburd3180 8 วันที่ผ่านมา

    I have been using a pause at the end of the run. The chromatogram does not like this. Peak shifts to the left changing from volume to time.

    • @UnicornStuff
      @UnicornStuff 2 วันที่ผ่านมา

      I have a whole series of videos about navigating modules so you can get the chromatogram you are looking for. They were some of the first videos I did, if you haven't seen them I'd recommend checking them out, th-cam.com/video/m5kp9wM63ZQ/w-d-xo.html

  • @9538503853
    @9538503853 หลายเดือนก่อน

    I am getting 0.mg/mL concetration even after providing the UV path length and ext.co effecient value. Please help me am i missing anything

    • @UnicornStuff
      @UnicornStuff 26 วันที่ผ่านมา

      It's hard to know what's going on with the information you provided. Tell me more or message me a snap shot of your chromatogram. Here are some guesses about what I think is going on. Did you integrate the peak? The area integrated needs to just be the peak of interest. Be sure the baseline is properly drawn/calculated, you can really only adjust the baseline in the classic evaluation module (so far as I know). Sorry I didn't answer quickly...

  • @user-vt6kk5io1t
    @user-vt6kk5io1t 2 หลายเดือนก่อน

    Thanks for the very helpful video. Do you equilibrate the slurry with water before or after you add them to the column?

    • @UnicornStuff
      @UnicornStuff หลายเดือนก่อน

      Good question. Ideally you should do it before, the slurry will settle very quickly if it is fully equilibrated, but if you don't mind waiting for it to settle then you can do it while it is on the column.

  • @kevinweiss1980
    @kevinweiss1980 2 หลายเดือนก่อน

    Some possible ideas for future videos....1) Pressure measurement in ÄKTA Systems 2) Setting delay volumes in ÄKTA Systems. 3) Column care and maintenance (Superdex Increase) Thanks!

    • @UnicornStuff
      @UnicornStuff หลายเดือนก่อน

      Thanks for the idea!

  • @amrutabapat4215
    @amrutabapat4215 3 หลายเดือนก่อน

    Nice video! How do I see all settings in an already saved method?

    • @UnicornStuff
      @UnicornStuff หลายเดือนก่อน

      Click on the text tab in the middle of the screen, go to 2:43 mark in this video to see what I'm talking about. You'll have to read through the method to find the setting you want. Once you find the setting be sure to press the change button, then save. Good luck.

  • @pprb123
    @pprb123 3 หลายเดือนก่อน

    Nice video! Adds some fun to lab work. I can never remember how to change pressure units between mPa and psi in unicorn 7. Can't find it in the user manual. Any thoughts?

    • @UnicornStuff
      @UnicornStuff 2 หลายเดือนก่อน

      Thanks, I'm glad you like the video! You can change the unit for results. in any of the modules go to Tools in the menu bar and select Options. Then in the window that pops up select the View tab, towards the bottom of the tab there is an option for Pressure Unit. It doesn't look like you can change the units in the Method Editor or System Control, only for results. It's a good question though.

  • @saschb
    @saschb 3 หลายเดือนก่อน

    Thanks for sharing your knowledge in a really clear and helpful way!

    • @UnicornStuff
      @UnicornStuff 3 หลายเดือนก่อน

      Glad it was helpful! I don't know why this video was such a challenge to make, probably because everyone is going to have something different, so I'm glad you liked it enough to comment.

  • @user-sv5gn6nu3j
    @user-sv5gn6nu3j 4 หลายเดือนก่อน

    Hi, can you upload column-packing videos??

    • @UnicornStuff
      @UnicornStuff 4 หลายเดือนก่อน

      I hope to soon. I have so many ideas and each video takes a bit to make. Is there a kind of column in particular you want to see packed?

    • @user-sv5gn6nu3j
      @user-sv5gn6nu3j 4 หลายเดือนก่อน

      HIC

    • @UnicornStuff
      @UnicornStuff 2 หลายเดือนก่อน

      Done! I did one, I should have some more up sometime in the near future. Not making any promises. th-cam.com/video/z02_8-yjmOk/w-d-xo.html

  • @tylerfield6447
    @tylerfield6447 5 หลายเดือนก่อน

    These videos are super helpful. I don't think there are any other resources out there like this for AKTA. I was wondering, if you have a loop valve with 5 loops, can you run scouting using five different inlets that each would store different proteins in each of the five loops. Then each loop could be desalted one by one? The first step would be IEX and the second step would be desalting.

    • @UnicornStuff
      @UnicornStuff 5 หลายเดือนก่อน

      Yeah you could, you'd either need two valves plumbed like the outlet valve or one like the column valve. There's no reason you couldn't have a second column valve you'd just have you use your imagination when it came to understanding the flow path.

  • @tonimaakter6673
    @tonimaakter6673 5 หลายเดือนก่อน

    Thank you for such a nice explaination, i am new to Äkta system and this helps me a lot :)

    • @UnicornStuff
      @UnicornStuff 5 หลายเดือนก่อน

      Glad it was helpful! Really means a lot! I'm trying to gear this channel towards people, such as yourself, that are new to the Avant and other ÄKTA systems.

    • @tonimaakter6673
      @tonimaakter6673 5 หลายเดือนก่อน

      ☺@@UnicornStuff Wish your channel gets more views and more people learn from here. Surprisingly, when I search for Äkta, the recommendation did not come directly; it only came up when I searched with Unicorn. Such a nice channel.❤

  • @sosolalavideos
    @sosolalavideos 9 หลายเดือนก่อน

    Thank you! This was very helpful, as we had some ancient runs which we could not delete…

    • @UnicornStuff
      @UnicornStuff 8 หลายเดือนก่อน

      What really! I never imagined someone would actually use my content. So excited my videos actually fill a need. Cheers!

  • @sthsb
    @sthsb 9 หลายเดือนก่อน

    Thank you for sharing, it's really helpful.

    • @UnicornStuff
      @UnicornStuff 9 หลายเดือนก่อน

      Glad it was helpful! It can be really helpful to get the hang of Unicorn and the Avant at first.

  • @sonicli8315
    @sonicli8315 ปีที่แล้ว

    Hi there, Why do you have two peaks when doing step elution?

    • @UnicornStuff
      @UnicornStuff 11 หลายเดือนก่อน

      Good question. There could be a variety of reasons all of which could be true in this case. There could be impurities in the sample that elute later. There could one target protein, but it is heterogeneous because of post transnational modifications. I believe the best answer however is the concentration of salt wasn't strong enough to get all the protein off for that step. The solution would be to increase the step length or concentration a little bit. Sorry for the late reply.

  • @ciciyali
    @ciciyali ปีที่แล้ว

    Thank you so much! It really helps me a lot.

    • @UnicornStuff
      @UnicornStuff ปีที่แล้ว

      You're welcome! I'm planning on making more videos.

  • @lindaxu4319
    @lindaxu4319 ปีที่แล้ว

    Excellent teaching ! Learning something new every time 👍

  • @haopeng9295
    @haopeng9295 ปีที่แล้ว

    why not use sodium hydroxide for CIP?Thanks

    • @UnicornStuff
      @UnicornStuff ปีที่แล้ว

      Great question. Most protein A type resins will foul if you use >10 mM NaOH because the ligand is unstable in higher concentrations. There are some NaOH resistant resins MabSelect (Cytiva) and Toyopearl (Tosoh) are my two favorite.

  • @haopeng9295
    @haopeng9295 ปีที่แล้ว

    question: when purgae pump head, is it necessary to turn on system flow? Thanks

    • @UnicornStuff
      @UnicornStuff ปีที่แล้ว

      No it is not, one of the check valves is always open. It is necessary to pump wash the system afterwards regardless. Thanks for your question.

  • @lindaxu4319
    @lindaxu4319 ปีที่แล้ว

    Excellent teaching!thank you so much !

  • @lindaxu4319
    @lindaxu4319 ปีที่แล้ว

    Excellent teaching!👍thank you!

  • @lindaxu4319
    @lindaxu4319 ปีที่แล้ว

    Thank you so much for the teaching 👍🙏it is very helpful ! by the way ,the back ground music is a little bit noisy if you don’t mind me saying !

    • @UnicornStuff
      @UnicornStuff ปีที่แล้ว

      Thanks for your feedback. I'm working on using the audio editor more. I'd like to have background music to cover up some of the breathing noises I make. Hopefully we find something we both like.

    • @lindaxu4319
      @lindaxu4319 ปีที่แล้ว

      @@UnicornStuff I see. Understand! Thank you so much! I

  • @lindaxu4319
    @lindaxu4319 ปีที่แล้ว

    Very useful , very clear explanation for a beginner ! thank you so much !any more in this Unicorn software?

    • @UnicornStuff
      @UnicornStuff ปีที่แล้ว

      Thanks! Yes I'm making more & super excited you found my channel!

    • @lindaxu4319
      @lindaxu4319 ปีที่แล้ว

      @@UnicornStuff looking forward to seeing more about how to use the unicorn software , methods editor and results evaluation 🙏👍