- 113
- 796 368
Zoeller Company
United States
เข้าร่วมเมื่อ 1 เม.ย. 2014
Zoeller Company was founded in 1939 as a family-owned operation making various products, one of which was a dependable column sump pump.
From its humble beginnings, Zoeller Company, one of the oldest, independently-owned U.S. pump manufacturers, has maintained the highest of quality standards, setting the benchmark for all other manufacturers of pumps. All Zoeller pumps are time-tested and quality-driven. Our submersible pumps are 100% factory-tested underwater for dependability from the instant they're plugged in.
Zoeller products are sold throughout the United States, Canada and Mexico as well as around the world. With five distinct wholesale product lines, Zoeller has the answer to all your pumping needs.
From its humble beginnings, Zoeller Company, one of the oldest, independently-owned U.S. pump manufacturers, has maintained the highest of quality standards, setting the benchmark for all other manufacturers of pumps. All Zoeller pumps are time-tested and quality-driven. Our submersible pumps are 100% factory-tested underwater for dependability from the instant they're plugged in.
Zoeller products are sold throughout the United States, Canada and Mexico as well as around the world. With five distinct wholesale product lines, Zoeller has the answer to all your pumping needs.
Shark Series 818 & 820 Grinder Pumps
Zoeller offers a variety of grinder pumps to meet the needs of your application. This video highlights our 818 & 820 models!
Learn more: zoellerpumps.com/product-category/pumps/grinder-pump/
Learn more: zoellerpumps.com/product-category/pumps/grinder-pump/
มุมมอง: 15
วีดีโอ
Pivot Panel Alarm Conditions
มุมมอง 39วันที่ผ่านมา
Jeff Sloss, Zoeller Controls Manager, walks through all the different alarm conditions on the Pivot, Pivot Pro, and Pivot Pro Control Panels. He explains what each alarm is for, shows you what they look like and walks you through how to reset them. Learn more about Pivot Control Panels: zoellerpumps.com/pivot-series-resource/ CHAPTERS: 00:00 - Introduction 01:09 - Alarm Condition #1 Overload is...
Zoeller Pump Sizing Program
มุมมอง 7321 วันที่ผ่านมา
This webinar covers Zoeller Pump Company's Pump Sizing Programs available on the zoellerpumps.com website. It walks through the software, best practices, and goes through a couple example sizings. Link to referenced Pump Sizing Document: zoellerpumps.com/wp-content/uploads/sites/3/2024/11/Pump-Sizing-Questionnaire.pdf
Fractional Horsepower Grinder Pumps
มุมมอง 2821 วันที่ผ่านมา
Zoeller's Fractional HP Grinder Pumps, Models 803, 805 & 807 can handle an entire household of 'flushable' materials. The stainless steel Tri-Slice Cutter provides over 250,000 cuts per minute. Watch our 803 1/2 HP Grinder at work. Lear more: 803 1/2 HP Grinder zoellerpumps.com/product/model-803-grinder-pump/ 805 3/4 HP Grinder zoellerpumps.com/product/model-805-grinder-pump/ 807 1 HP Grinder z...
Pivot RL Control Panel Overview
มุมมอง 4721 วันที่ผ่านมา
The Pivot RL is a 1 Ph, 115/208/240 V, Simplex Control Panel with basic LEDs, buzzer, globe, and dry contacts. This is an entry level panel often used in septic and effluent applications where you don't need all the advanced logic and features that come standard in our other Pivot Panels. Pivot RL Product Pages: 51354-0001 zoellerpumps.com/product/simplex-pivot-rl-control-panel-0-20-amps/ 51354...
GRIND TIME TUESDAY - Model 810 & 815 Progressing Cavity Grinder Pumps
มุมมอง 2421 วันที่ผ่านมา
We're back with another GRIND TIME TUESDAY! This week, Zack Cooper, Zoeller's National Sales Manager, dives into the features and benefits of the Model 810 and 815 Shark Series Progressing Cavity Grinder Pumps. Learn more about these models: zoellerpumps.com/product.../pumps/grinder-pump/ #GrindTimeTuesday #GrindTime #GTT #SharkSeries #SharkInTheWater #ZoellerGrinders #ZoellerGrinderPumps #Zoel...
Zoeller Solutions for Septic System Applications
มุมมอง 2414 หลายเดือนก่อน
Zoeller Solutions for Septic System Applications
GRIND TIME TUESDAY - Model 807 Grinder Pump Features & Benefits
มุมมอง 924 หลายเดือนก่อน
GRIND TIME TUESDAY - Model 807 Grinder Pump Features & Benefits
Shark Series Grinder Offering Webinar
มุมมอง 1224 หลายเดือนก่อน
Shark Series Grinder Offering Webinar
Build Your Dream Bathroom with a Qwik Jon Toilet System
มุมมอง 2Kปีที่แล้ว
Build Your Dream Bathroom with a Qwik Jon Toilet System
Pivot Panels - Smart Float Logic Explained
มุมมอง 2.2Kปีที่แล้ว
Pivot Panels - Smart Float Logic Explained
Pivot Panels - Basics About Float Switches
มุมมอง 1.9Kปีที่แล้ว
Pivot Panels - Basics About Float Switches
Pivot Panels - Connect & Monitor with the Z Control Cloud
มุมมอง 1.1Kปีที่แล้ว
Pivot Panels - Connect & Monitor with the Z Control Cloud
Pivot Panels - Overview of Panel Components
มุมมอง 977ปีที่แล้ว
Pivot Panels - Overview of Panel Components
Zoeller Wastewater Pumps - What's in your pump housing?
มุมมอง 1.1Kปีที่แล้ว
Zoeller Wastewater Pumps - What's in your pump housing?
Qwik Jon Premier Unboxing/Installation Video
มุมมอง 21Kปีที่แล้ว
Qwik Jon Premier Unboxing/Installation Video
Recirculating Media Filters Overview Webinar
มุมมอง 544ปีที่แล้ว
Recirculating Media Filters Overview Webinar
Zoeller Specialty Products Overview Webinar
มุมมอง 3332 ปีที่แล้ว
Zoeller Specialty Products Overview Webinar
Zoeller Environmental Products Overview Webinar
มุมมอง 2282 ปีที่แล้ว
Zoeller Environmental Products Overview Webinar
Zoeller Engineered Products Overview Webinar
มุมมอง 3432 ปีที่แล้ว
Zoeller Engineered Products Overview Webinar
Pretreating High Strength Waste for Huber's Orchard and Winery
มุมมอง 1752 ปีที่แล้ว
Pretreating High Strength Waste for Huber's Orchard and Winery
Upflush & Other Remodeling Solutions Webinar
มุมมอง 1.7K2 ปีที่แล้ว
Upflush & Other Remodeling Solutions Webinar
Excellent teaching!
🌭🥩🧽
I have a zoeller check valve what screws direct to the pump so were would i be best drilling?
Need, wiring diagram for a,pak deluxe 10\0623alarm
Clark Mark Miller Laura Perez Shirley
INSTALATIONS PLEASE
While I have built a number of controllers... they have been for my personal use. No competition with me, your unit looks like a great product. Yes, with three switches 2^3 conditions or 8... but when you consider that the sequence is expected. When odd combinations occur outside of the normally occurring states, that really adds to the 'is this alarm-worthy?, or should we continue to run the pump, or try the other?" Quite important when flooding the building is a risk. Thanks for the video.
SUGGESTION: Zoeller should have product registration on this type of pump (or all pumps) so when there are recalls or known issues customers can be notified. I was literally laughed at by one of their distributors when asked why a Zoeller water powered pump had failed. He laughed and told me they don't even sell that unit any longer as it is well documented it had reliability issues. It would have been nice if the manufactured would have notified its customers that a new, more reliable unit was recommended BEFORE their finished basements flood!
Why are there (nearly) no videos on the 540 water back up pump? if this pump has been out for over 4 years now why is no one using this? I'm guessing its lack of confidence as Zoeller's history with water powered back up pumps is not very good. I have installed multiple Zoeller water powered back up pumps in the past (not this unit) and they are plagued with problems so until I see more professionals using this I remain cautious. I do love the electric pumps.
0:12
If you want to seal the drain tile pipe into the side of the basin, what is the recommended method with these fiberglass tanks? Is there a slightly curved bulkhead fitting that seals better without cracking or distorting the tank wall? Insert a t? Uniseal?
The best pump on the Market. I have used Zoeller pumps for 35 yrs or more. Great pumps.
We always love to hear that! Thank you for the support!
My Opinion is that Considering the High Cost of Labor, It Just Pays to Buy the best one. It's not worth having to Replace it. I bought an M95 and Zoeller was Very Helpful on the Phone. I am Just using it for a hole that fills from a Washing Machine and a Central AC. Works Great! th-cam.com/video/JQPq6MJDNog/w-d-xo.html
What is your answer to the switch housing filling with water making it not work? This has been a common problem with these pumps that seems like it will never be addressed.
Hi @petebusch9069. To learn more about our switch options, and speak directly with our experts, please email zcotechnical@zoeller.com or call 1-800-928-7867 and dial option 6. I hope this helps!
@@ZoellerCompany My God, a canned answer with a phone number to a person that knows nothing and call that customer service. You corporate people will never get it. Now go do your job and find the person that knows the answer to this and post it so we can all see how your products have developed over the years and how you solved older problems using new technology but you purposely hide these people as though they might say something that you don't want out in the public. FFS people, get a clue.
We're sorry sir, however, we would like to discuss your specific application and the issues that you seem to be having. We can not go into detail on the comments section of this video. We are more than willing to discuss and will stand behind the product.
@@ZoellerCompany Ok, water gets inside your switches, all of them, what have you changed to prevent that and why are you not willing to talk about that publicly? This is the weak link in your pumps and is what keeps me from buying them. We use these in a sump pump and actually depend on them working to avoid flooding our basement. Having a high quality float is of the utmost importance and is the number one failure. As a consumer I want to know if your doing anything about this or not? As of yet I don't see anything new. So far I've received nothing but canned corporate answers from you. Yes or no, are your float switches the same as they've always been and if not what are the changes made? Your entire customer base wants to know this.
@@ZoellerCompany Ok, so you just told whoever is reading this you don't care and have not done a thing to improve your floats. Good luck.
Too bad the float switch fails and will leak water into the housing on these pumps.
Hi @petebusch9069. We have a few different switch options available for our pumps. If you would like to learn more about them, our experts in product support would be more than happy to walk you through the available choices. To connect with them, you can either email zcotechnical@zoeller.com or call 1-800-928-7867 and press option 6 to be connected with them. I hope this helps!
@@ZoellerCompany Why not just address the issue instead of providing a canned response that does nothing but give your company a bad reputation? You have good pumps but your floats are junk, we all know that and end up using other floats. Do you really think avoiding that issue is in you best interest? Do you really think your fooling you customers? If you would just come out and say yes, this is the weak point and this is what we are doing about it then you might gain some respect. We all know you have a phone number, providing that does not help.
Thank you so much
Thank you VERY much for this video, extremely helpful and very well done
Glad it was helpful!
Good advice I have a pedestal sump pump no problem 4 months, but if I change over I'll do as u say thanks for this video
What’s the gallon per inch for an 18” basin? The basin volume per depth table starts at 24”, but most residential applications are using the smaller 18” x 30” size.
An 18” diameter basin has 1.1 gallons per inch. Hope this helps!
What is included with the pump? succion pipe and float? How deep can we place the bottom of the succion pipe?
Good afternoon! Our installation instructions for this product have a lot of the details it sounds like you're looking for. You can check that out here: zoellerpumps.com/wp-content/uploads/sites/3/2023/10/FM3170.pdf (parts list on page 7) (Installation of suction pipe on page 3) Also, please note the suction pipe is NOT included. I hope this helps!
I am a plumber and own and operate a pump servicing company. This was as well of done video as I have seen in a while and will be sharing it during our on boarding procedures. Thanks again and keep up the excellent work!
Thanks for the positive feedback! We're glad you liked it and found it beneficial!
Nice - helpful video
Thanks @sklinkner. Glad it was helpful!
@@ZoellerCompany I have a 10-0093 controller with what I now understand to be a Stop float which is working intermittently. This was clear after watching the video but wasn't easy to figure out from the written docs I was initially able to find online. Basically if Lead LED is on and Stop LED is off, that's an unexpected state.
How does the controller calculate pump runtime? I have a new unit that I installed only a few days ago and I’ve only run it for testing yet it says it has 2 days of runtime on it. I did have the controller plugged in without the pump plugged in for a day or 2.
Good morning! Should you require technical support or troubleshooting assistance for your application our Product Support team is more than happy to help out! They can be reached by emailing zcotechnical@zoeller.com or calling 1-800-028-7867 and selecting option 6. I hope this helps!
Where can I get extra o-Rings?
Good morning! If you call into our Product Support Department they can get some to you! Email zcotechnical@zoeller.com or call 1-800-928-7867 extension 6.
If you know the hole get clogged easily, why not design it differently?
Great delivery from the presenter. The cholesterol joke hit. Good info!
What would cause the 2A control power fuse blow in a simplex? I cleaned off a float that was jammed up and put it back in. I am waiting on fuses. Could it be something else?
Good morning! If you reach out to our product support department by emailing zcotechnical@zoeller.com or by calling 1-800-928-7867 and pressing option 6, our product experts can help you troubleshoot your specific application. I hope this helps!
How do i prevent freezing of a pump that must be outside?
Good morning! Our Product Support experts would be more than happy to help you troubleshoot your specific application. You can reach them at zcotechnical@zoeller.com or by calling 1-800-928-7867 and pressing option 6. I hope this helps!
Thank you!
Wow using a black table really helps us see the pump! Not!!!
Sorry it's a bit difficult to see on the table in the video. We do offer in person training in our 6,000 square foot facility where you and your team can see the pumps up close and in person and see our full demos all guided by our specialists with years of experience at Zoeller and in the field. If you're interested, you can reach out to your local Zoeller Rep for more details. (Rep List: www.zoellerpumps.com/sales-support/sales-representatives/). Here is also a link to more details on a visit: www.zoellerpumps.com/training/zoeller-university/zoeller-university-on-campus/. We can tailor experiences to just the things you and your group want to see or cover. We hope you'll consider seeing them in person with us sometime.
good video
Glad you enjoyed
How do you convert a standard float switch M53 to use a float-less LN style switch? What parts to order? What is used for the pump top?
So, since this video was made we have stopped selling the LN switches. We used to offer a specific Part Number pump that CAME with them. We do have SEVERAL other switch options though despite dropping the Floatless. If you contact our Product Support department at 1-800-928-7867 and press option 6, or email them at zcotechnical@zoeller.com, one of our product experts will help you find the best available switch for your application and be able to provide you with the exact part numbers you would need. I know this isn't exactly what you were hoping to see, but I hope it helps!
Why don’t they just come with a pre-drilled vent hole?
Our Model 53 does come with a pre-drilled vent hole on the pump that you can see in the cover photo for this video, but that can become clogged up on the pump fairly easily. If a check valve is used, we recommend drilling a vent hole in the discharge pipe. This hole should be located within the basin between the pump and check valve, usually a few inches above the pump “on” level but below the pit cover. The vent hole will prevent air-locking from occurring. It's a pretty small step to prevent a bigger headache from happening down the road. We hope this helps! Should you have any further technical questions, please contact our tech support team at zcotechnical@zoeller.com or 1.800.928.7867 and press option 6.
Can this be installed in a laundry room and use the washing machine drain as the waste drain for this type of toilet. The washing machine drain also used as vent line it goes to top of roof.
Good morning! We have a product support department that can answer your question. You can either email zcotechnical@zoeller.com or call them by dialing 1-800-928-7867 and pressing option 6. I hope this helps!
I was not aware that there is a vent line forming part of the system.
Anything that drains whether by gravity or pressure needs a vent to work properly or in some cases to work at all. 👍
How many psi does the 2 inch 3 hp create
For technical questions, you can reach our Product Support experts at 1.800.928.7867 (and press option 6) or email them at zcotechnical@zoeller.com. I hope this helps!
Great intro video! I need help with my M137-D. Two years old and I had to replace the capacitor (no big deal), but after only two weeks the pump is throwing the breaker. I cannot find any obvious signs for failure, and am looking for specs on ohms, etc. to troubleshoot the capacitor etc. Also, the schematic is helpful, but actual pictures of the wiring would be VERY helpful. Anyone know of a good website with photos and troubleshooting values? Oh, the impeller spins easily, there were no signs of water in the pump, etc. Thanks!
Good morning! We have an entire department that offers Technical Support. You can reach them at 1.800.928.7867 (and press option 6) or email them at zcotechnical@zoeller.com. They should be able to help you troubleshoot your application and/or point you to some great resources. I hope this helps!
What is your recommendation for somewhere like Los Angeles with unpredictable, inconsistent rain? We got soaked this year, 40”+. Large amounts of rainfall all at once with these storms. Now in the summer and fall we’ll get no rain for 6 months. Seems unlikely that the pump can stay submerged year round.
Hi! Our Product Support experts can help you out with this! You can either call them at 1.800.928.7867 and press option 6, or you can email them at zcotechnical@zoeller.com. I hope this helps!
My 2hp sewage pump setup worked flawlessly for 3 years but now the weep hole keeps getting clogged. Do you think my cutter is dull and allowing too many solids out of the discharge??
Good morning! Our technical support staff can help you troubleshoot your application. You can reach them by emailing zcotechnical@zoeller.com or by calling 1.800.928.7867 and pressing option 6.
Good talk, would have liked more visuals.
I see some distributer see the model M98-0001 and some sell the M98-0006, does anyone know what differences are?
"Fantastic source of information." Is it? you made a presentation for 40 minutes of video and did not talk about what it is- Weep Hole on the side of yours product. in my case, the hole rusted because the pump did not work for a year. the hole has been stuffed. But even this is not the problem, the problem is that the motor does not spin at a speed to raise the water to the required height. i checked the pump in october and it was working, now end of april the pump is no longer working
Good morning! This webinar is on our sump pump line and the switch options that are available with them. If you're having an issue with your product we recommend you reach out to our product support department at zcotechnical@zoeller.com or by calling 1.800.928.7867 and pressing option 6. Our product experts would be more than happy to troubleshoot the issues you're experiencing. I hope this helps!
What is considered a small pit versus a large pit? It would be helpful to give a general guideline range of small v. large pits.
Good morning! If you reach out to our Product Support department at zcotechnical@zoeller.com or call them at 1.800.928.7867 and press option 6 they can answer your question regarding pit size and might even be able to provide some helpful materials for you depending on what you're doing/details you're needing. I hope this helps!
The top of the line LN series pump switch is already listed as obsolete, one year after your webinar. Zoeller, please explain..
Unfortunately, the switches utilized in the LN "Floatless Series" pumps became unavailable causing us to obsolete the series. We apologize for any issues this may cause but would be more than willing to assist in selecting a switch style for your application, if needed. To assist you with this our Product Support experts can be reached at zcotechnical@zoeller.com or by calling 1.800.928.7867 and pressing option 6. I hope this helps!
Very good explanation. Thanks!
Glad it was helpful!
Does anyone know the procedure for refilling the pump housing. Is mineral oil used or machine oil? How much oil is used? Enough to cover the miter completely?
Hi - if you contact our Product Support department at zcotechnical@zoeller.com or by calling 1.800.928.7967 and pressing option 6, they should be able to answer this for you.
I’m still getting a 3-beep alarm after recharging my sump pump’s back-up battery and confirm it’s in Good status at an Auto Zone. There was never an Input 1 LED/alarm. Is it possible this alarm is going off because of low AA back-up batteries in the alarm itself?
Hi - if you contact our Product Support department at zcotechnical@zoeller.com or by calling 1.800.928.7967 and pressing option 6, they should be able to walk you through the issue you're experiencing and provide a solution. Hope this helps!
Had my grinder replaced in June 2022. Have had problems with pump alarms going off after 3 months. Have had the plumber out her numerous times over the last 6 months. They keep replacing parts and now the alarm go off every time we run water, run dishwasher, washer, take showers etc. They want to replace more parts, but I feel I can't trust it. They need to replace the entire panel, but as of this date they will not. Buy something else.
Good morning. I'm sorry to hear you're having trouble with one of our pumps. We do have a talented team of product support specialists that might be able to help you troubleshoot your application if you would like to contact them they can be reached at zcotechnical@zoeller.com or 1-800-928-7867, extension 6.
If this is a problem why not dril it from factory?
We do include a predrilled 3/16" vent hole on a lot of our bottom intake pumps, but we still recommend a 3/16" hole be drilled in the discharge PIPE between the discharge of the pump and the bottom of the check valve, just in case the predrilled hole we made in the pump body gets clogged. I hope this helps!