- 564
- 1 119 443
CST ChillingSolutionsTraining
Colombia
เข้าร่วมเมื่อ 5 มี.ค. 2021
Channel for training in the area of Mechanical engineering, specializing in the area of refrigeration and air conditioning
Centrifugal vs. Peripheral Water Pumps: Choosing the Best Cost Efficiency and Applications Explained
Centrifugal vs. Peripheral Water Pumps: Choosing the Best Cost Efficiency and Applications Explained
มุมมอง: 17
วีดีโอ
How the Most Affordable Air Conditioner Works: No Compressor, No Water - Peltier Effect!
มุมมอง 184 ชั่วโมงที่ผ่านมา
How the Most Affordable Air Conditioner Works: No Compressor, No Water - Peltier Effect!
How to Fix Samsung Fridge Ice Maker Error Code 26E: Troubleshooting & Solutions
มุมมอง 167 ชั่วโมงที่ผ่านมา
How to Fix Samsung Fridge Ice Maker Error Code 26E: Troubleshooting & Solutions
How to Fix Samsung Refrigerator Error Code 25E: Causes, Symptoms, and Solutions Explained!
มุมมอง 4712 ชั่วโมงที่ผ่านมา
How to Fix Samsung Refrigerator Error Code 25E: Causes, Symptoms, and Solutions Explained!
Electric Car Parts and How They Work: Battery, Motor, and EV System Explained
มุมมอง 17814 ชั่วโมงที่ผ่านมา
Electric Car Parts and How They Work: Battery, Motor, and EV System Explained
Samsung Refrigerator Fan Error Codes 22E & 23E: Causes, Fixes, and Diagnostic Guide
มุมมอง 4319 ชั่วโมงที่ผ่านมา
Samsung Refrigerator Fan Error Codes 22E & 23E: Causes, Fixes, and Diagnostic Guide
Electric AC Compressor for Cars: Pros and Cons You Need to Know Before Buying
มุมมอง 382วันที่ผ่านมา
Electric AC Compressor for Cars: Pros and Cons You Need to Know Before Buying
Samsung Refrigerator Error Code 22E: Causes, Diagnosis, and Easy Fixes
มุมมอง 77วันที่ผ่านมา
Samsung Refrigerator Error Code 22E: Causes, Diagnosis, and Easy Fixes
What Happens if You Turn On a Refrigerator Right After Moving It? Risks and Tips
มุมมอง 63วันที่ผ่านมา
What Happens if You Turn On a Refrigerator Right After Moving It? Risks and Tips
Why Does a Frost-Free Fridge Build Up Ice in the Freezer? Causes and Solutions Explained
มุมมอง 24วันที่ผ่านมา
Why Does a Frost-Free Fridge Build Up Ice in the Freezer? Causes and Solutions Explained
Why Does My Refrigerator Compressor Turn On and Off? 10 Causes and Easy Fixes
มุมมอง 4314 วันที่ผ่านมา
Why Does My Refrigerator Compressor Turn On and Off? 10 Causes and Easy Fixes
Why Does My Refrigerator Compressor Overheat? 10 Top Causes & Fixes
มุมมอง 2714 วันที่ผ่านมา
Why Does My Refrigerator Compressor Overheat? 10 Top Causes & Fixes
How to Fix Black or Contaminated Car AC Compressor Oil: Essential Steps and Tips
มุมมอง 15014 วันที่ผ่านมา
How to Fix Black or Contaminated Car AC Compressor Oil: Essential Steps and Tips
Crankshaft Position Sensor CKP Codes P0335 P0336 P0337 P0338 P0339 : Function, Issues, Diagnosis
มุมมอง 8914 วันที่ผ่านมา
Crankshaft Position Sensor CKP Codes P0335 P0336 P0337 P0338 P0339 : Function, Issues, Diagnosis
P0534 A/C Code: Refrigerant Leak Causes, Diagnosis & Quick Fix for Auto AC
มุมมอง 2914 วันที่ผ่านมา
P0534 A/C Code: Refrigerant Leak Causes, Diagnosis & Quick Fix for Auto AC
How to Detect Low Refrigerant or Gas Leaks in Car AC: Symptoms and Solutions
มุมมอง 6621 วันที่ผ่านมา
How to Detect Low Refrigerant or Gas Leaks in Car AC: Symptoms and Solutions
How H-Block Expansion Valves Work & Fail in Automotive AC: Diagnosis & Symptoms Explained!
มุมมอง 14021 วันที่ผ่านมา
How H-Block Expansion Valves Work & Fail in Automotive AC: Diagnosis & Symptoms Explained!
How to Diagnose and Troubleshoot a Non-Inverter Refrigerator Compressor: Step-by-Step Guide
มุมมอง 7121 วันที่ผ่านมา
How to Diagnose and Troubleshoot a Non-Inverter Refrigerator Compressor: Step-by-Step Guide
HOW TO TEST AC COMPRESSOR VALVE ON A CAR: POA Function, Stroke Control in Piston Compressors
มุมมอง 7221 วันที่ผ่านมา
HOW TO TEST AC COMPRESSOR VALVE ON A CAR: POA Function, Stroke Control in Piston Compressors
Automotive AC Compressor Failure: Causes, Symptoms & Diagnosis Guide
มุมมอง 35121 วันที่ผ่านมา
Automotive AC Compressor Failure: Causes, Symptoms & Diagnosis Guide
R134a vs. R1234yf: Comparing Pressures, Efficiency, and Performance in Automotive AC Systems
มุมมอง 6028 วันที่ผ่านมา
R134a vs. R1234yf: Comparing Pressures, Efficiency, and Performance in Automotive AC Systems
Digital Scroll Compressor with R410A: Operation, Pressures, and Troubleshooting Guide
มุมมอง 229หลายเดือนก่อน
Digital Scroll Compressor with R410A: Operation, Pressures, and Troubleshooting Guide
How Fan Coil and Air Handling Units Work Together: Air Recirculation Explained
มุมมอง 101หลายเดือนก่อน
How Fan Coil and Air Handling Units Work Together: Air Recirculation Explained
Fan Coil Unit (FCU) in HVAC Systems: Types, Components, and Operation
มุมมอง 150หลายเดือนก่อน
Fan Coil Unit (FCU) in HVAC Systems: Types, Components, and Operation
Top Signs of a Bad Car AC Pressure Sensor & How to Diagnose Quickly: How to working:
มุมมอง 178หลายเดือนก่อน
Top Signs of a Bad Car AC Pressure Sensor & How to Diagnose Quickly: How to working:
Portable AC Troubleshooting: Common Issues, Causes, and Easy DIY Fixes for Better Cooling
มุมมอง 159หลายเดือนก่อน
Portable AC Troubleshooting: Common Issues, Causes, and Easy DIY Fixes for Better Cooling
Automotive AC Refrigerants Explained: R134a vs R1234yf - Parts, Types & Performance
มุมมอง 90หลายเดือนก่อน
Automotive AC Refrigerants Explained: R134a vs R1234yf - Parts, Types & Performance
Automotive AC Pressure Chart for R134a Refrigerant | Ideal High and Low Pressure Readings Explained
มุมมอง 432หลายเดือนก่อน
Automotive AC Pressure Chart for R134a Refrigerant | Ideal High and Low Pressure Readings Explained
How to Diagnose a Bad AC Compressor? Signs and Testing Procedures
มุมมอง 419หลายเดือนก่อน
How to Diagnose a Bad AC Compressor? Signs and Testing Procedures
AC Leaking Water Indoors? Causes and Fixes for Water Dripping from Indoor Unit
มุมมอง 83หลายเดือนก่อน
AC Leaking Water Indoors? Causes and Fixes for Water Dripping from Indoor Unit
Wonderful! Keep it up!
От души. Вполне понятно и информативно для слайдового видео с автоозвучкой
R410A is a mixture of 50% R32 and 50% R125 (the fire suppressor to R32) to be used in domestic and building occupied.
We have a Fredrick Air-conditioning, filter cleaned, and vents but want start.
Can r600 be use for car A/C?
El rendimiento seria bajo, porque a medida que la temperatura del evaporador aumenta cae su eficiencia
So many problems in one error code f9
GODREJ Model no R B EON NXW 405 SD/2015 FROST FREE 405 Liter Problem in E3
R410a is better
Now I know.... 1million thanks...
Excelente. Thanks.
What a terrible day to have ears
Can i use r134a compressor on my chest freezer.. is it going to cooler and ice than r600a
Can I use r134a compressor on chest freezer
How about R410A, can be Replace by R404A? Oil its same POE oil..
thanks for sharing
great video, i wish you upload a beter cuality, thanks a lot.
Keep it up sir
Sir midea cassette inverter ac error code L3 what Mean
The electrical power is 236v can it cause problem?
The electrical power is 236v can it cause problem?
The power is 236v
Hello sir My air conditioner five time odu light blinking floor mounted unit non inverter I search code show problem cool freeze or heting over where is problem my unit please let me know
It's all a scam people
I had that dF code before
Parabéns pelo vídeo nota 10
Miller Cynthia Rodriguez Carol Johnson John
That's the same thing to me sometimes
Thanks a lot sir
my GREE inverter (barely out of box) start doing this .... damn !!!!
Good day, Thank you for the quality content. My name is Ivan. I represent the Aclima Academy, which conducts training in Ukraine and Poland. Can we translate and use your videos to teach our students?
nice info...
What about General
Hi i need R22 gas
I do not understand? why the temperature in the evaporator coil is lower when the pressure on the low side is lower aka is 'low' on refrigerant? To me it would be logic if it was the other way around. Can someone explain that?
Here's the previous response translated into English: When there is lower pressure, a liquid evaporates more easily because its molecules separate more quickly due to the reduced force they need to overcome. For this reason, at lower pressures, the liquid boils faster and requires a lower temperature to reach its boiling point.
@@CSTChillingSolutionsTraining Thank you very much for your answer. This sounds logical and I need more time to let this sink in to understand it regarding to the sealed loop system. Thank you!
capillary 0.6 compresseur 1/6 refregerant 134a langueur........?
👌👌👌
Terrible voice quality (levels too high, distortion, robo-voice?), music is not helping either.
Mine did this last winter. If this winter again, I will follow your steps. During summer normal cooling functions well without errors.
Thank you 😂🫶 I was worried I already messed up my new aircon.
Why does it happen?
for that stupid people can ask
It literally in the video
@@تَعَلَّمْتَرْتَقِيthanks for nothing. What a garbage response
@@randynBroncos I didn't tell him the reason because it's literally mentioned in the first 20 seconds
As explained I the video, it could be a number of reasons why this happens. But the main reason is because the refrigerant pressure is either too high or too low.
Pokemon ass evolution line
I am a transport refrigeration technician for Mitsubishi and Topre here in the Philippines,,, but I still dream of learning Thermo King
Some memories come out from my mind ❤
453a is solid.
Thanks a lot! This type of explaination is not easy find it.
An important point was missed. The GWP effect is when there is a LEAK! not while it's in the system. When & IF it leaks when there is a fire, it will propagate the fire!!! Also, very important flammable A2L (R32 or R454B) might and could INTERNALY explode. This is true if the vacuum process (must be higher than R410A an A1 class non-flammable, non-explosive class) is not perfect (presence of moisture/oxygen) as when compressed the temperature could reach the lubricating OIL ignition temperature, and in the presence of flammable refrigerant (any A2, A2L or worse A3) the oil might ignite the flammable refrigerants! This possibility will not exist if A1 class non-flammable refrigerants are present. Neil Afram Director of Space Air Ltd. distributor of AC & Heat Pumps since 1980. Standards & Regulation relating to refrigerants classes ASHRAE 34/15 & ISO 817/5149
An important point was missed. The GWP effect is when there is a LEAK! not while it's in the system. When & IF it leaks when there is a fire, it will propagate the fire!!! Also, very important flammable A2L (R32 or R454B) might and could INTERNALY explode. This is true if the vacuum process (must be higher than R410A an A1 class non-flammable, non-explosive class) is not perfect (presence of moisture/oxygen) as when compressed the temperature could reach the lubricating OIL ignition temperature, and in the presence of flammable refrigerant (any A2, A2L or worse A3) the oil might ignite the flammable refrigerants! This possibility will not exist if A1 class (R410A, or CFC, HCFC R22) non-flammable refrigerants are present. Neil Afram Director of Space Air Ltd. distributor of AC & Heat Pumps since 1980. Standards & Regulation relating to refrigerants classes ASHRAE 34/15 & ISO 817/5149
An important point was missed. The GWP effect is when there is a LEAK! not while it's in the system. When & IF it leaks when there is a fire, it will propagate the fire!!! Also, very important flammable A2L (R32 or R454B) might and could INTERNALY explode. This is true if the vacuum process (must be higher than R410A an A1 class non-flammable, non-explosive class) is not perfect (presence of moisture/oxygen) as when compressed the temperature could reach the lubricating OIL ignition temperature, and in the presence of flammable refrigerant (any A2, A2L or worse A3) the oil might ignite the flammable refrigerants! This possibility will not exist if A1 class non-flammable refrigerants are present. Neil Afram Director of Space Air Ltd. distributor of AC & Heat Pumps since 1980. Standards & Regulation relating to refrigerants classes ASHRAE 34/15 & ISO 817/5149
An important point was missed. The GWP effect is when there is a LEAK! not while it's in the system. When & IF it leaks when there is a fire, it will propagate the fire!!! Also, very important flammable A2L (R32 or R454B) might and could INTERNALY explode. This is true if the vacuum process (must be higher than R410A an A1 class non-flammable, non-explosive class) is not perfect (presence of moisture/oxygen) as when compressed the temperature could reach the lubricating OIL ignition temperature, and in the presence of flammable refrigerant (any A2, A2L or worse A3) the oil might ignite the flammable refrigerants! This possibility will not exist if A1 class non-flammable refrigerants are present. Neil Afram Director of Space Air Ltd. distributor of AC & Heat Pumps since 1980. Standards & Regulation relating to refrigerants classes ASHRAE 34/15 & ISO 817/5149
Will a simple one amp fuse do that job???