PFS Flow Metering Solutions
เข้าร่วมเมื่อ 16 ก.พ. 2018
PFS is The Leader in Flow Measurement Solutions. Primary Flow Signal offers world-class differential pressure flow elements that ensure the highest quality, accuracy and reliability for liquid, gas, and steam applications.
Brilliant PS Rising Main 1 (2018 inspection)
video from 2018 showing water coming in from the meter vault wall where the high pressure impulse line exits the meter vault.
มุมมอง: 23
วีดีโอ
Bruecken PS Rising Main 2 flow meter
มุมมอง 396 หลายเดือนก่อน
showing the situation with Bruecken PS RM2 in the venturi meter vault. In the background audio you can hear the water flowing through the impulse piping until I close the valve and it goes silent. The impulse lines going to the building are 1.5" (or maybe 2") so there must be a fair amount of water flow when there should be none.
24990 Rosemount 2051 transmitter menu LOI
มุมมอง 38911 หลายเดือนก่อน
24990 Rosemount 2051 transmitter menu LOI
24786-01 "chirping"
มุมมอง 27ปีที่แล้ว
During calibration this meter was occasionally producing an unusual "chirping" or short whistle type noises.
PFS low flow gravimetric calibration setup
มุมมอง 2192 ปีที่แล้ว
PFS low flow gravimetric calibration setup
Venturi flow meter - rodding out a mostly plugged pressure tap
มุมมอง 4694 ปีที่แล้ว
A series of filter effluent flow meters at a large Water Treatment Plant were showing sings of "plugging" of the pressure taps, specifically in the "low pressure" taps. This quick video shows the difference between a partially plugged tap and a clear tap.
Rosemount 3051CD DP transmitter Low Flow Cutoff
มุมมอง 1.8K5 ปีที่แล้ว
Rosemount 3051CD DP transmitter Low Flow Cutoff
K2 HS Impulse Lines - partial plugging is likely
มุมมอง 325 ปีที่แล้ว
The Left impulse line has a slow trickle of water with the ball valve wide open. The other impulse line has a strong jet of water in comparison.
shelter rock 2 - partial plugging of impulse line
มุมมอง 1745 ปีที่แล้ว
Note the change in flow from the low pressure bleed valve after it is opened. This is clear signs of a partial blockage in the impulse lines, usually occuring at the pressure ports at the venturi meter.
Rosemount 3051CD transmitter mA output affected by 475 HART communicator
มุมมอง 5585 ปีที่แล้ว
raw video: When "communicating" with a Rosemount 3051CD3 transmitter using an Emerson 475 HART communicator there was a small but easily measurable drop in the mA output signal. At the start of this clip the transmitter had already been Zero Trimmed and the applied DP is 0.0" H2O (xmtr ranged 0.0"-69.1" = 0.0-15.0 MGD : Square Root Transfer Function). The mA output is slightly high (around 4.00...
Rosemount 3051S3CD2 - changing Primary Variable from Pressure to Scaled Variable
มุมมอง 9K5 ปีที่แล้ว
a quick demonstration showing the current zero error effect, zeroing the transmitter, and changing the Primary Variable to Scaled Variable.
ABB 266DSHH - replacing electronics board
มุมมอง 2.2K5 ปีที่แล้ว
replacing the electronics board in an ABB 266 DP transmitter due to "unreliable output current" error.
Rosemount 3051DP transmitter - over-Range / over-Limit
มุมมอง 5095 ปีที่แล้ว
This Rosemount 3051CD1 transmitter is currently ranged 0-15.0" Water Column = 0 - 1.00 MGD with the LCD showing flow rate in MGD. The CD1 model has an upper range limit (URL) of 25" H2O. This video demonstrates how this transmitter will respond if the flow rate was higher than it was ranged for. ( 0:00 to 0:22 ) With DP up to 15" the transmitter works normally and shows the correct flow rate. (...
Yokogawa DPHarp Transmitter configuration without a HART communicator
มุมมอง 24K6 ปีที่แล้ว
Yokogawa DPHarp Transmitter configuration without a HART communicator
Turbine flow meter - averaging pulse output (Hz) from two pickups on one turbine meter.
มุมมอง 1.4K6 ปีที่แล้ว
Turbine flow meter - averaging pulse output (Hz) from two pickups on one turbine meter.
Siemens Hydroranger configuration with XRS-5 Transducer on a PFS Halmi Nozzle
มุมมอง 3526 ปีที่แล้ว
Siemens Hydroranger configuration with XRS-5 Transducer on a PFS Halmi Nozzle
Rosemount 3051S Differential Pressure transmitter - mA output after being underwater
มุมมอง 2406 ปีที่แล้ว
Rosemount 3051S Differential Pressure transmitter - mA output after being underwater
Rosemount 3051S Differential Pressure in a flooded vault
มุมมอง 756 ปีที่แล้ว
Rosemount 3051S Differential Pressure in a flooded vault
Record as found and then reconfigure from factory settings. Upload AF. If that doesn’t work, try another xtmer or configure from DCS.
Hindi mein video banao
Masterpiece
Eu não sabia que poderíamos alterar parâmetros sem uma Programadora, grato pela informação.
Yo vivo en Tocoa colon mi nombre es santos isabel zuniga
Nesesito intalación de yotu
What is Low cutt off what is the used?