Jason Johnson
เข้าร่วมเมื่อ 11 ต.ค. 2012
Dedicated to all things HVAC
MEGGER TESTING OF A #DAIKIN #WSC CENTRIFUGAL.
MEGGER TESTING OF A #DAIKIN #WSC CENTRIFUGAL.
มุมมอง: 354
วีดีโอ
EDDY CURRENT TESTING ON A 425 TON #DAIKIN #WSC CENTRIFUGAL
มุมมอง 682 ชั่วโมงที่ผ่านมา
EDDY CURRENT TESTING ON A 425 TON #DAIKIN #WSC CENTRIFUGAL
Short week with Thanksgiving. Worked on some ARU's this week. Happy Thanksgiving weekend to yall.
มุมมอง 29928 วันที่ผ่านมา
Short week with Thanksgiving. Worked on some ARU's this week. Happy Thanksgiving weekend to yall.
FRIENDS.....WELCOME TO DUCTWORK NATIONAL FOREST.
มุมมอง 4.7Kหลายเดือนก่อน
FRIENDS.....WELCOME TO DUCTWORK NATIONAL FOREST.
2 JOHNSON AIR ROTATION UNITS HAVING ISSUES WITH HEATING. WALK THROUGH OF UNIT.
มุมมอง 457หลายเดือนก่อน
#Johnson #airrotation #fault17 #mainflamefailure
A LITTLE TOUR OF THIS BUILDING AND THE EQUIPMENT. #WSC #CVHE #boilerroom
มุมมอง 355หลายเดือนก่อน
A LITTLE TOUR OF THIS BUILDING AND THE EQUIPMENT. #WSC #CVHE #boilerroom
ITS A GOLDEN UNICORN.....A CRANE ON THE ROOF...MADE THINGS SO NICE AND EASY. WORKING ON 130 TON RTUs
มุมมอง 3492 หลายเดือนก่อน
ITS A GOLDEN UNICORN.....A CRANE ON THE ROOF...MADE THINGS SO NICE AND EASY. WORKING ON 130 TON RTUs
Faulty entering water temp sensor was keeping the chiller off #daikin #awv
มุมมอง 4522 หลายเดือนก่อน
Faulty entering water temp sensor was keeping the chiller off #daikin #awv
DAIKIN WME's ARE DOWN....LACK OF PROPER MAINTENANCE MADE IT RUN OUT OF SPECS. #daikin #wme
มุมมอง 5392 หลายเดือนก่อน
DAIKIN WME's ARE DOWN....LACK OF PROPER MAINTENANCE MADE IT RUN OUT OF SPECS. #daikin #wme
You can use 2 vacuum pumps at the same time and have success with it.
มุมมอง 1.1K2 หลายเดือนก่อน
When using 2 vacuum pumps of different size it can be a challenge to have one pump not overpower another and suck the oil out of the lesser pump. Another way is to pipe the pumps in parallel. They share a common header. Im actually thinking about getting a pipe of 1.5"-2" and adding in taps to allow for a parallel configuration. I would add hose taps on the sides and the end would be able to co...
Its charging day.#Daikin #AWS #aircooled
มุมมอง 9222 หลายเดือนก่อน
I was showing my coworker how to charge if he was working on a centrifugal chiller. It works for your larger air cooled as well
ANOTHER CHILLER, BOTH CIRCUITS....RESONATE FREQUENCY.....PUKING OIL AND REFRIGERANT #AWS #AIRCOOLED
มุมมอง 6172 หลายเดือนก่อน
#daikinaws #chillerlife #commercialhvac #economizer
AFTER HOURS CALL. 2 WME MAG BEARING CHILLERS DOWN AT A HOSPITAL
มุมมอง 6772 หลายเดือนก่อน
AFTER HOURS CALL. 2 WME MAG BEARING CHILLERS DOWN AT A HOSPITAL
SHOWING HOW TO INTERFACE WITH A COPELAND MOTOR PROTECTOR, USING A LAPTOP
มุมมอง 3642 หลายเดือนก่อน
SHOWING HOW TO INTERFACE WITH A COPELAND MOTOR PROTECTOR, USING A LAPTOP
Finishing the trio compressor repair. The end is when we figure out what likely killed the old ones
มุมมอง 5913 หลายเดือนก่อน
Finishing the trio compressor repair. The end is when we figure out what likely killed the old ones
A LITTLE OT ACTION. ON SITE TO MAKE SURE SHUT DOWN AND START UP WAS SUCCESSFUL.
มุมมอง 2983 หลายเดือนก่อน
A LITTLE OT ACTION. ON SITE TO MAKE SURE SHUT DOWN AND START UP WAS SUCCESSFUL.
THE CONCLUSION OF THIS JOB. UPDATE FIRMWARE AND SOFTWARE FOR THE MT3 AND BACNET. GET IT RUNNING.✌️
มุมมอง 3373 หลายเดือนก่อน
THE CONCLUSION OF THIS JOB. UPDATE FIRMWARE AND SOFTWARE FOR THE MT3 AND BACNET. GET IT RUNNING.✌️
CONVERTING 2 AIR COOLED CHILLERS FROM TXV'S TO EEV'S. SOFTWARE AND FIRMWARE UPDATES
มุมมอง 5293 หลายเดือนก่อน
CONVERTING 2 AIR COOLED CHILLERS FROM TXV'S TO EEV'S. SOFTWARE AND FIRMWARE UPDATES
Another day in HVACland. Working on a 200 ton AHU, (2)100 ton condensers and a 68 ton AHU.
มุมมอง 7K3 หลายเดือนก่อน
Another day in HVACland. Working on a 200 ton AHU, (2)100 ton condensers and a 68 ton AHU.
Back in the lab again. Doing my best to explain how a solid state (triac) speed controller operates.
มุมมอง 1093 หลายเดือนก่อน
Back in the lab again. Doing my best to explain how a solid state (triac) speed controller operates.
Type of equipment you could run into on any given day in Heavy Commercial HVAC.
มุมมอง 3.3K4 หลายเดือนก่อน
Type of equipment you could run into on any given day in Heavy Commercial HVAC.
I love an easy Friday. Happy HVACing everyone
มุมมอง 2874 หลายเดือนก่อน
I love an easy Friday. Happy HVACing everyone
2 CHILLERS HAD ISSUES WITH CIRCUIT 2.ONE OF THEM PUKED ITS GUTS OUT. PLUS FOUND A POTENTIAL RUB OUT
มุมมอง 7444 หลายเดือนก่อน
2 CHILLERS HAD ISSUES WITH CIRCUIT 2.ONE OF THEM PUKED ITS GUTS OUT. PLUS FOUND A POTENTIAL RUB OUT
Hopefully I'll start to have some more interesting and informative content coming soon.
มุมมอง 2624 หลายเดือนก่อน
Hopefully I'll start to have some more interesting and informative content coming soon.
Got the trainer board up and running. Little lesson on thinking about how electricity works.
มุมมอง 1.7K5 หลายเดือนก่อน
Got the trainer board up and running. Little lesson on thinking about how electricity works.
Back in the lab. Made myself a multi use trainer. Just having some fun with some old parts.
มุมมอง 4015 หลายเดือนก่อน
Back in the lab. Made myself a multi use trainer. Just having some fun with some old parts.
MAKING AN INEXPENSIVE FLARE ADAPTER TO USE LARGER HOSES FOR RECOVERY, VACUUM, AND CHARGING
มุมมอง 4765 หลายเดือนก่อน
MAKING AN INEXPENSIVE FLARE ADAPTER TO USE LARGER HOSES FOR RECOVERY, VACUUM, AND CHARGING
Something satisfying about cleaning coils. A little PM work on these (2) 350 ton air cooled RTAC'S.
มุมมอง 5385 หลายเดือนก่อน
Something satisfying about cleaning coils. A little PM work on these (2) 350 ton air cooled RTAC'S.
REPLACING THE SATURATED AND COMPRESSOR SUCTION REFRIGERANT SENSORS. USING THE SUBCOOLER AS WELL.
มุมมอง 2K6 หลายเดือนก่อน
REPLACING THE SATURATED AND COMPRESSOR SUCTION REFRIGERANT SENSORS. USING THE SUBCOOLER AS WELL.
Nice vid JJ ... Those Fluke meggers are pricey aren't they ? Thx
@Eddy63 yeah they aren't cheap but very much worth it though. Thanks for stopping by
Electromagnetic Induction 😁
@@FroggieBeluga pretty much. As the guy put it electromagnetic saturation.
@@jasonjohnsonHVAC in the search of field deprivation
How many tons of chiller do you have in that one room? Nicely done, thanks for taking us along Jason.
@@EverythingHVACR 425 tons. 1194lbs of 134a
Just a little guy, lol.
@@fshn76 just a wee little lass.
Sorry Steve-o I didn't read your question correctly. In the mechanical room is probably 1200 tons. This chiller is 425
@ all good brother, I appreciate you.
Always interesting content! Thanks, Jason
@EverythingHVACR thanks brother. Hope the new gig is going well.
@ right back at ya brother, we’ll have to catch up again soon.
OAT causing hell and costing a lot.
@@petermuller161 all truth
Just a quick question I am very interested in making this however I am not sure what to buy for the heat exchanger think you could help me out with this just a bit?
@@MrApplied this subcooler has ⅜" port adapters with ¼" connectors, one ¼" port adapter with ¼" connector. Used 56% silver brazing rods. Does this answer your question?
@ yes but also like you think I can get this on eBay maybe?
Didn’t really show up on the video but I could def hear the shaking. If that lets loose it could do some major damage.
@fshn76 yeah it was shaking pretty good. I shut it down and let the building know it wasn't recommended to run.
chilly? what, 56*? Buffalo is going for 3 ft lake affect, miss it?
@@neilcvids2583 it was 37° that morning
22 this morning in N Georgia
sounds like a steam locomotive, happy TG you and family
@@neilcvids2583 Happy Thanksgiving to yall
Cant see it but can hear it😁 🚂🚃🚃🚃🚃
@FroggieBeluga it was a shaking like a disco in the 70's 😆 🤣
Bearing problems? Happy thanksgiving brother.
I was thinking that or possibly a hub issue. You can definitely hear those blade tips hitting the shroud
I didn't dig into it, as it was the end of the day on Wednesday. Its off for now.
Hey Jason, 5000hr lube timer?. I’ve never seen that, 1000hr-1200hr max. With shutdown at 1500hr for no lube. Was there any particular reason for the insulation test?, suffering from instantaneous current faults?. Looks to be a Q3 or Q4 compressor maybe about 300tons?.
@jeffreyrex8232 im not sure why the timer is set that high. Megger testing is just a part of routine maintenance of who i was employed with at the time. I have to do the same thing where im employed now as well on annuals.
It's cool, but where is it located?
What the hell am I looking at?? _"Labs...All labs in...this facility..."_ Ahh yes, Racoon city plumbing and heating service call, should have guessed. But in all seriousness, that's a beauty of an engineering space. You know it's gold plated when there's even fire extinguisers buried throughout up there. "No expenses spared"
This is what’s in the ceiling of the backrooms
Need to color code it
i have a copper fin 2 solid red alarm no water flow. pressure reading 0. any idea what it can be?
@@EmmanuelShahid7 i would start by confirming you have water and that the pump works. You can jump out the pump contacts.....after you confirm there is water in the loop. I don't always trust analog gauges in a hydronic system.
@jasonjohnsonHVAC thanx bro I will take a look at it. I work at the VA BOILER and working 2 month. they were using the regulater valve with the little handle to maintain at 30 to 35 psi. I check last night was running fine but was around 45 psi which was a concern. I came in tonight and it was down. water circular pump was running but no pressure at all. I tried resetting a few time on the copper fin side and turning it on and off and no luck. I will try your method as you mentioned.
>when the forest is cleaner than my house 😅😅😅 great vid mane, cheers
This is intense
Wow, do you have a ball of string so you can find your way back?
@@FrankBenlin 😆...thought did cross my mind though
satisfactory factorys be like ...lol
Almost some ASMR type content, which is very nice!😂 I have no clue what any of the ducts or equipment does, but it would be interesting to know. Maybe a future video can explain some more of what each of those pieces of equipment does in the sector? Nice video anyway👏👍
@icicle_man4971 this ductwork is for labs. The equipment keeps the labs at precise temps, humidity and pressure for what is needed
Mario Bros without the color rendering. I bet the Princess isn't there either.
@@blaydCA 😆
Cant be that critical if the sprinkler pipe is screwed not welded.
Some games really have to work on their level design
That things in good shape
@Blakethegoat proper maintenance and they run like a champ.
Semiconductor fab interstitial level above cleanroom ceiling?
@Hammerthumb1 not semiconductor, but bioscience labs
I knew it was clean room after his 2 second pan of the "plenum" area.
You could get lost up there.
@@geniferteal4178 fo real
Never seen anything like this. Very cool. Thanks for sharing!
@@syntaxerorr 🤙🤙
woah
@@BasedBidoof my thoughts exactly when I seen it
3:00 "madness" Ie: _"I've encountered something much bigger than me 😨"._ Yep! Welcome! There's a lot of us here, in this world.
Those humidifiers: I guess from the name they’re steam injection; is the steam generated in the unit, or is there a remote steam generator?
@chriswalford4161 it is injected from the humidifier itself. What i like about this one is there is no canister to replace. It has a stainless steel box where the heaters are. It's a fairly simple unit mechanically.
Speaking of stepping… Yeah tripping over one of those pendant heads for the fire suppression would be a bad day.
@@mysock351C 😆😆
Great place to film the next Diehard movie.
@@mysock351C John McClain......HVAC detective
I wonder if some kind of tuned-mass damper attached near the fitting could solve the problem. Just attaching the proper length of thin wire rope with a hose clamp near the fitting could do the trick. You could probably tell when the vibrations were damped by touch.
@@projectartichoke there is a kit for it, which has been installed
That's just unreal! I never thought about such spaces existing. Wow, the man hours designing and installing all of that must be astronomical.
@@projectartichoke i was told it took 8 months for just the ductwork alone. They have to have the airflow balanced and certified every year. It's pretty impressive
And an army of inspectors.
I feel sorry for the guy who has to do the air balancing
@bigcatauna lol...it has to be checked and certified every year.
Its actually relatively easy when it comes to these places because everything is close to spec and acessible. I say relative because the hardest part about air balancing these is having to go into clean room environment.
I feel itchy
@@ElonMusk-hx8yw i wouldn't ever want to be an insulation tech....I definitely wouldn't have wanted to to this job either.
lost in the backrooms gah damn
@@KennytheHedgehog619 banished to the depths of hvacland
Beautiful spectacle of nature. It truly is an insane place though..
@Jonas_Keunecke whoever installed it and wrapped it did a really good job. It looks professional. Appreciate you stopping by and checking out the video
new backrooms level unlocked
@@theonecommenter secret poker games and brothel.
Brother you've entered the Backrooms. Godspeed to you
@@Majilikin hahahaha....thats was a good one
I'd knock that tin all day, but you gotta pay someone else to wrap it lol.
Im that took awhile to do
never seen firemaster look so nice 🤩
@@ziggymartinez2273 it was done nicely. I was told all that ductwork alone took over 8 months to do.
That duct work is just insane, but also interesting seeing the mix of black iron, copper and stainless piping up there. And the miles of EMT as well. Wondering if they have like road signs up there though, seems like getting lost in there would be pretty easy.
@@sparkplug1018 hahahaha it is easy to get lost if you are looking for something specific. Bioscience building so many different types of piping for various different types of uses
What kind of ceiling are you walking on? Very curious, yeah any kind of high tech facility will look like this, this is a seriously busy place
@shockingguy panels for labs that are pressure dependent. Some are positive, some are negative pressure.
micro chip plants are pretty thick too
@heathhill7802 its a bioscience facility. Many different labs with positive or negative air pressure. It's interesting
@@jasonjohnsonHVAClooks pretty much the same as semiconductor clean rooms.
I want to see the air handler
@Epiccatsandkittens there are 90 and 60 ton rooftops. I believe this roof for all those labs there were 6 RTU'S up there. Not just a conventional rtu. I have a previous video where I replaced a trio set of compressors on a 90 ton
Good lookin interstitial
@@jasonbliemeister3690 🤜🤛