![Advantage Heating & Cooling](/img/default-banner.jpg)
- 235
- 685 159
Advantage Heating & Cooling
United States
เข้าร่วมเมื่อ 20 พ.ค. 2016
I’m a one-man HVAC shop working the trade for over 30 years, self-taught from trial and error, Doing installs, repairs, and maintenance for Heating, Ventilation, and Air conditioning; my channel consists mainly of videos doing those things. Started my business in 2006. I recently started having my 19-year-old son work with me to learn what it takes in this business. This way, he will have some skills to make things happen.
HVAC: GE Motor Module furnace Repair for $7
You can repair many GE (Regal-Beloit) ECM motor modules damaged by voltage problems and power surges. The repair Kit requires the use of a soldering gun (or iron) and rosin core (for electronic use)
Ametherm Ntc Thermistor - SL22 1R020 amzn.to/3Wiz8NU
Ametherm Ntc Thermistor - SL32 1R030 amzn.to/4dkHMST
60W Portable Soldering Iron Kit with Ceramic Heater, 5 Tips, Stand, Solder amzn.to/3AaqhGu
Ametherm Ntc Thermistor - SL22 1R020 amzn.to/3Wiz8NU
Ametherm Ntc Thermistor - SL32 1R030 amzn.to/4dkHMST
60W Portable Soldering Iron Kit with Ceramic Heater, 5 Tips, Stand, Solder amzn.to/3AaqhGu
มุมมอง: 44
วีดีโอ
Repairing This Old Amana AC Saves thousands!
มุมมอง 16914 วันที่ผ่านมา
Shopping on Amazon? Please use my referral link amzn.to/3KCQz65 TitanPro TRCFD405 HVAC Round Dual Motor Run Capacitor. 40/5 MFD/UF 440/370 Volts amzn.to/4fdlXX0 In this video, we tackle repairing an old Amana AC unit, showcasing how a DIY approach can save you thousands of dollars in HVAC repair costs. By demonstrating the process of fixing this old appliance, we provide valuable insights into ...
Upgrade your HVAC System With Bosch's Most Efficient Heat Pump!
มุมมอง 64928 วันที่ผ่านมา
Upgrade your HVAC system for better efficiency with Bosch! Learn how to save on energy bills, qualify for tax credits up to $2000, and increase your home comfort. Shopping on Amazon? Please use my referral link amzn.to/3KCQz65 www.energystar.gov/about/federal-tax-credits/air-source-heat-pumps
Goodman Furnace No Heat Fix: Customer's Money Pit!
มุมมอง 6023 หลายเดือนก่อน
In this video, we tackle a common issue with Goodman furnaces - no heat! In this case, the customer is determined to keep dumping money into their furnace, but is it really worth it? Watch as we troubleshoot and fix the problem, saving both time and money in the process. Don't let your furnace become a money pit - learn how to properly maintain and repair it to avoid costly repairs in the futur...
Southwest Michigan HVAC Contractor Installs Zoning System for Ultimate Home Comfort
มุมมอง 783 หลายเดือนก่อน
Welcome to our channel! This video showcases our HVAC contractor in southwest Michigan installing a zoning system for ultimate home comfort. Zoning systems allow for customized temperature control in different areas of your home, ensuring optimal comfort and energy efficiency. Watch as our team expertly installs this system, providing a glimpse into the process and benefits it offers. Contact u...
The Truth About Diversitech Condensate Pumps
มุมมอง 9633 หลายเดือนก่อน
Need to get in touch? Please email me at advanhvac@gmail.com Shopping on Amazon? Please use my referral link amzn.to/3KCQz65 Rechargeable Tactical Flashlight Holster High Lumens Rechargeable Flashlights - 21000 Candela, 1900 Lumens with 5000 mAh Long Lasting Cell amzn.to/4cKSsuz This video reveals the truth about Diversitech Condensate Pumps and why they may not be the best choice for your HVAC...
Achieving Zen Balancing Waterfalls and an HVAC Business. Pond less waterfall being built time-lapse
มุมมอง 1724 หลายเดือนก่อน
lwls.net/ In this mesmerizing time-lapse video, watch as we achieve Zen by balancing waterfalls while showcasing LWLS expertise. Follow along as we construct a stunning pondless waterfall, blending the beauty of nature with their technical skills. Whether you're a nature lover or interested in our HVAC services, this video offers a unique blend of relaxation and professionalism. Sit back, relax...
Goodman Furnace no Heat. Sensor needed cleaned.
มุมมอง 1684 หลายเดือนก่อน
Housecall Pro link.hscll.com/etb0z Need to get in touch? Please email me at advanhvac@gmail.com Donations Accepted: CashApp: $AdvantageHeating This video tackles a common issue with Goodman furnaces - no heat! But don't worry, we've got an easy fix for you, with a special perk from one of our customers. Watch as we troubleshoot and resolve the issue, ensuring your home stays warm and cozy. This...
Faulty Hot Surface Ignitor On Bryant Furnace Causes No Heat!
มุมมอง 2914 หลายเดือนก่อน
Shopping on Amazon? Please use my referral link amzn.to/3KCQz65 Need to get in touch? Please email me at advanhvac@gmail.com Donations Accepted: CashApp: $AdvantageHeating This video tackles a common issue with Bryant furnaces-a faulty hot surface ignitor that causes no heat in your home. We walk you through the diagnostic process and show you step-by-step how to replace the ignitor to get your...
EcoBee 3 Thermostat Installation
มุมมอง 1384 หลายเดือนก่อน
ecobee3 Lite Smart Thermostat - Programmable Wifi Thermostat - Works with Siri, Alexa, Google Assistant - Energy Star Certified - DIY Install, Black amzn.to/3PsrfTC This step-by-step guide will show you how to install an EcoBee3 Light Pro Thermostat in your home. This smart thermostat offers energy-saving features and convenient controls to help you optimize your home's heating and cooling syst...
The Dirty Furnace Filter Program Explained
มุมมอง 2224 หลายเดือนก่อน
Shopping on Amazon? Please use my referral link amzn.to/3KCQz65 Here are links to the tools I use, And it costs you nothing extra to buy from this list: OLIGHT Swivel 400 Lumens LED Work Light:amzn.to/407lxcc Need to get in touch? Please email me at advanhvac@gmail.com Donations Accepted: CashApp: $AdvantageHeating Welcome to the Dirty Furnace Filter Program: A Step-by-Step Guide! This comprehe...
Fixing No Heat on Goodman Furnace: Drain Pressure Switch Troubleshooting
มุมมอง 7034 หลายเดือนก่อน
Shopping on Amazon? Please use my referral link amzn.to/3KCQz65 Here are links to the tools I use, And it costs you nothing extra to buy from this list: OLIGHT Swivel 400 Lumens LED Work Light:amzn.to/407lxcc Supco FPRO100 Furnace Pro Switch Clip amzn.to/3TFBrdN Need to get in touch? Please email me at advanhvac@gmail.com Donations Accepted: CashApp: $AdvantageHeating Are you experiencing issue...
Goodman Furnace Emergency Service: No Heat Fix
มุมมอง 4424 หลายเดือนก่อน
Goodman Furnace Emergency Service: No Heat Fix
Cleaning a Very Dirty Dryer Vent and Electric Dryer Guide
มุมมอง 9944 หลายเดือนก่อน
Cleaning a Very Dirty Dryer Vent and Electric Dryer Guide
Amana Downflow Gas Furnace Blower Limit Reset.
มุมมอง 4295 หลายเดือนก่อน
Amana Downflow Gas Furnace Blower Limit Reset.
Troubleshooting no heat on a Bryant Plus 90 furnace
มุมมอง 1.3K5 หลายเดือนก่อน
Troubleshooting no heat on a Bryant Plus 90 furnace
A Risky Gas Leak turned into a Furnace Change out!
มุมมอง 5535 หลายเดือนก่อน
A Risky Gas Leak turned into a Furnace Change out!
How many parts were changed on this furnace was it worth it?
มุมมอง 3835 หลายเดือนก่อน
How many parts were changed on this furnace was it worth it?
Fixing a 35 Year Old Bryant Gas Furnace with a Plugged Heat Exchanger!
มุมมอง 1.3K6 หลายเดือนก่อน
Fixing a 35 Year Old Bryant Gas Furnace with a Plugged Heat Exchanger!
Fixing Amana/Goodman AMVC96 E2 Low Stage Pressure Switch Error
มุมมอง 9566 หลายเดือนก่อน
Fixing Amana/Goodman AMVC96 E2 Low Stage Pressure Switch Error
Adventures in Furnace Replacement: Confronting Another Failed York Heat Exchanger
มุมมอง 2.1K6 หลายเดือนก่อน
Adventures in Furnace Replacement: Confronting Another Failed York Heat Exchanger
Troubleshoot and Fix No Heat Issue: Amana Gas Furnace RollOut Switch Explained
มุมมอง 1.5K6 หลายเดือนก่อน
Troubleshoot and Fix No Heat Issue: Amana Gas Furnace RollOut Switch Explained
The Hidden Danger in Your Home: The Importance of Dryer Vent Cleaning
มุมมอง 2647 หลายเดือนก่อน
The Hidden Danger in Your Home: The Importance of Dryer Vent Cleaning
Upgrading Your Furnace: Armstrong Change-out with New Unit and Ductwork
มุมมอง 9637 หลายเดือนก่อน
Upgrading Your Furnace: Armstrong Change-out with New Unit and Ductwork
The Ultimate Fix: No Heat on Christmas Day with a Rheem Gas Furnace!
มุมมอง 9967 หลายเดือนก่อน
The Ultimate Fix: No Heat on Christmas Day with a Rheem Gas Furnace!
Revamping Efficiency: Unveiling Our New HVAC Service Van! Merry Christmas
มุมมอง 4887 หลายเดือนก่อน
Revamping Efficiency: Unveiling Our New HVAC Service Van! Merry Christmas
🎉 Celebrating 96 Years of Wisdom and Laughter! 🎂✨
มุมมอง 777 หลายเดือนก่อน
🎉 Celebrating 96 Years of Wisdom and Laughter! 🎂✨
Reviving Heat: A Simple Solution to Furnace Troubles
มุมมอง 1.1K7 หลายเดือนก่อน
Reviving Heat: A Simple Solution to Furnace Troubles
Cleaning a flame sensor on a York furnace. How old will my Father be?
มุมมอง 3047 หลายเดือนก่อน
Cleaning a flame sensor on a York furnace. How old will my Father be?
Avoid These Costly Mistakes with York Furnace Heat Exchangers
มุมมอง 2.1K7 หลายเดือนก่อน
Avoid These Costly Mistakes with York Furnace Heat Exchangers
Good job.
DigiKey has the Inrush Current Limiter 1 Ohms ±20% 20 A 0.866" (22.00mm). NTC Thermistor. $1.94 + Shpg. The SL32 looked like 2 Ohms.
Good to know.
Great looking transition. Nice install.
You are awesome! Thank You!
Is it only required to pull a vac on the larger suction line or can the small suction line be used as well for evacuation before opening the valves ?
Great video. Any chance you found a 90° nozzle tip for using on mini splits? I ordered one, should be here on Saturday. I liked it bc you can connect to 110. The battery-operated ones seem to cost a lot more. Thanks again.
No, I do have the old school washers with the orange tank and built in battery. Those were really expensive.
You took it off at the wrong side. It is supposed to be spliced before the meter.
😆
Are there any links to order online?
Order what online my friend?
@@ADVANHVAC the bosch ids 2 ton
@@gerrylewis553 unfortunately not. Those are distribution based only.
Brand new and you didn't warranty it?!?!?!!!
@@kevinroberts781 read the pinned comment.
Great systems too perfect of work 😮
Drop the background music
Naw, I like it thanks for watching.
Your going to wish you installed that generator away from your deck and I let my generator run for three days with no problems never shut it down once in my area power outage is not uncommon I have one once a year it’s been 12 years since I installed mine still running great so it should last a good long time.
I install a lot of them Duncan’s/Lenox and I’ve realized a lot of them have LG compressors in them. I put four hard starts on in the past month.
This one was a 13 Seer and has Copeland Scroll, you are correct the new ones have LG. Knock on balsa wood that I have not have had any issues with any of them.
@@ADVANHVAC lol rightt
That's the name of the game I tell ya
Very nice install!!! Love the 🎶!!!
Wow, brand new unit tripping the breaker? I guess hard start as a temporary fix but I’d say you probably need to check that compressor.
Read pinned comment.
When changing from 3 phase to single phase the wiring size should have been increased and the breaker resized as well. Not resizing the wiring could have increased the voltage drop and increased the amperage draw as well.
Would it be okay to bury the line?
It would have to be the yellow pipe for it to be buried. Its plastic pipe for underground.
Warranty I think should of been best solution
Why? Did you read my pinned comment? Its been a year and everything is running as it should.
Hey you’re back… nice😏
Just a hint from a 40 year HVAC contractor .... dont install bottom line pile of JUNK builder model crap and you want have compressor issues from day one. Enough said. You can think me later
Agreed that's why I don't. 😂
Them pads are ugly af but I love the Bosch’s
Replacing a standard AC motor with an Chinesium Motor/PWM Controller is going backwards in reliability! 🙄
That was not a standard motor. It was an ECM. This is YORKS upgrade. This is why I don't install JCI anymore.
@@ADVANHVAC - With all the modern residential HVAC equipment today. I'd rather fix 20y/o hdw than drop $10-30K on this new & improved, guaranteed to fail 10 days past warranty period stuff. It seems like there's an epidemic of Chinesium parts on them, which means early failures!
@xxxxxxxxxx6903 I agree the older stuff that was made 30 years ago was built way better. Maybe not as efficient but built. The new stuff is geared to saving more money on the usage of Electric and Gas.
I’m going to show how OCD I am there’s no support after the gas meter🎉🎉🎉🎉
It's just fine! Thanks for watching 😁
Cheater cord
Bc they purchased a Garbage ass LG compressor. purchase an ac condenser w/ a Copeland Scroll
That's too bad! The Armstrongs used to have Copland Scrolls in them. I just confirmed with my supplier and you are correct they do have LG.This 13 Seer does have a Copeland scroll.
Not sure heavy duty cleaner is good for that customer’s lawn 😬
They have to mow it more now. 😁
6:57 Aluminum Rigid Offset wrenches are your friend, invest in a 14" and 18'.
Thanks just got a crescent and Rigid delivered today from home depot. Thank you for the suggestion.
@@ADVANHVAC Your welcome you will love them, they put the correct angle for leverage.
You should use a permeant marker and mark the stab depth of the fitting so you KNOW it is in deep enough.
That exact thing happened to me today 😡😡😡
It sucks.
Does this happen to be a Concord or an Air Ease condensing unit?
Armstrong
@@ADVANHVAC I had to put a hard start kit on a brand new AirEase (Armstrong) AC 2 months ago. Literally installed a full furnace and AC swap out. Pulled a vacuum. Opened service valves and first turn on……hummmmm. That’s happened twice on AirEase.
@rsmotox1 😮 really.
@@ADVANHVAC yeah it’s unfortunate bc I love the performance of the units. Their prices are getting out of hand as well (comparable to Bryant now. So I’ve decided to switch to using Bryant. Love the channel by the way. .
@rsmotox1 yes I know what you mean. I give my customers choices between Bosch, Armstrong, and Concord they seem to levitate towards Concord.
Hopefully it is not China “Bosch”
Is there any other?
Excellent work
3 Ton not 2!
This one is a 2-ton. By flipping the switch and matching evap coil.
Do you have to but a regulator on the line or was it just straight piped also wis the larger pipe size because of the distance the gas has to travel
Correct due to the length and the BTU that the generator pulls have to run the bigger line. No regulators on anything.
How much should a job like this cost me, guesstimate.
$500-$800
Multi split we had from 1988 in our home ( my father paid a fortune to install it , Daikin ) it worked fine above 25 years , i remember my room it was like freezer all the summer. Nice work
Hi, i need such help for myself too..But idk anything about fuses and such, so i cant risk doing it myself..My landlord can’t help either.. need to do something about this stupid noise..
JUST WISH I could do it 1/2 as fast as YOU !!! 🥵🥵
😂
Heat pump best for none freezing winters, otherwise you need an electric heat defroster to defrost the coils which makes it less efficient
Total BS. The math and physics tells me that a simple capacitor works just fine to start a motor..
Boards are like 2-3k with a wait time. No bypassing boards to get cooling or a simple part off truck. These boards fail with a slight spike in voltage .
I will be dropping a video soon about this. It happened to me. I actually think on this particular unit. Ugh😑
Are the newer Yorks any good? I’ve started seeing a lot of them in residential now
No they are still garbage.
Just don’t reverse the wites because you were reversed polarity on the fan it’ll run backwards, an you ‘ll smoke the motor😂😂😂
Surprised Bosch hasn’t incorporated the amp and volt readings in their software and equipment uploads to their app.
Something that I never disclosed!! until now. I don't typically do any commercial work. When I looked at this Job I did not look at the Phase of the Electrical and I should have. So we removed a 3 phase 4 ton AC the Unit needed much less due to it's on the Ground floor and 3 walls are under ground. I installed a 3 or a 3-1/2 ton so the power was 208 3-Phase the Ac is rated for 240-208. When i was hearing the compressor Instantly realized that I had one of the incorrect legs of power on it. So once I did some testing and switched the legs around and Added that HS everything is fine. This was a year ago and was just there about 3 weeks ago and everything is Normal.
Is this the seer 20 Bosch ? Does it vibrate much?
This is the 18 SEER . I have only installed one 20 and that didn't seem to shake at all. My clients love it.
@@ADVANHVAC Thank you for the information!
Hack with the best of them😅
You know it lol
Good work 🫡. If there is cavitation on the filter, dryer line Does that indicate the filter dryer bad?
❔ that wasn't the filter dryer that was the start capacitor.
Good call
As a professional, I would never use anything except pipe wrenches or adjustable crescent wrenches, big to tighten pipe up.