- 114
- 54 412
Electrical Supervisor
เข้าร่วมเมื่อ 24 ต.ค. 2023
The Channel Electrical Supervisor is the team of Electrical Engineer, Electrician, Technician & Electrical Fabricator
Channel provide the update of industrial electrical work of the following and many more
1) Electrical Panel dressing and termination
2) Cable selection
3) Cable gland selection
3) Hole Saw Cutting in entry plate of electrical panel
4) Hole saw cutter selection
5) Defferent types of Flame Proof/ Weather Proof industrial light fitting and termination
6) Motor Connection
7) Motor Starter
8) Sharing knowledge of Different types of Circuit breaker MCB, LCB, RCCB, MCCB & VCB
9)Centrifuge control panel connection
10) Reactor control panel connection
11) RTD connection
12) Temperature/ Humidity Senser installation and connection
13) Room cleaner
14) Knowledge of cable tray
15) Camera installation and connection
16) Data/Telephone panel connection
17) LCB testing
18) Electrical Panel thermography
19) Meggering
And Many more....
Channel provide the update of industrial electrical work of the following and many more
1) Electrical Panel dressing and termination
2) Cable selection
3) Cable gland selection
3) Hole Saw Cutting in entry plate of electrical panel
4) Hole saw cutter selection
5) Defferent types of Flame Proof/ Weather Proof industrial light fitting and termination
6) Motor Connection
7) Motor Starter
8) Sharing knowledge of Different types of Circuit breaker MCB, LCB, RCCB, MCCB & VCB
9)Centrifuge control panel connection
10) Reactor control panel connection
11) RTD connection
12) Temperature/ Humidity Senser installation and connection
13) Room cleaner
14) Knowledge of cable tray
15) Camera installation and connection
16) Data/Telephone panel connection
17) LCB testing
18) Electrical Panel thermography
19) Meggering
And Many more....
Air Compressor Fully Automatic Star Delta Starter Connection | Industrial Electrical Work
Air Compressor Fully Automatic Star Delta Starter Connection | Industrial Electrical Work
มุมมอง: 1 403
วีดีโอ
Electrical Changeover Cable Gland Termination Industrial Electrical Work
มุมมอง 1.7K5 หลายเดือนก่อน
Electrical Changeover Cable Gland Termination Industrial Electrical Work
FRP Cable Tray 90 Degree Bend | Electrical Cable Tray Fabrication Work
มุมมอง 1.7K5 หลายเดือนก่อน
FRP Cable Tray 90 Degree Bend | Electrical Cable Tray Fabrication Work
How to Bend FRP Cable Tray 90 Degree ? Electrical Cable Tray Installation | Industrial Work
มุมมอง 5815 หลายเดือนก่อน
How to Bend FRP Cable Tray 90 Degree ? Electrical Cable Tray Installation | Industrial Work
Centrifuge Control Panel Wiring and Connection | Industrial Electrical Work
มุมมอง 657 หลายเดือนก่อน
Centrifuge Control Panel Wiring and Connection | Industrial Electrical Work
Vaccum Circuit Breaker | VCB Short Video | Electrical Industrial Work #electrical
มุมมอง 777 หลายเดือนก่อน
Vaccum Circuit Breaker | VCB Short Video | Electrical Industrial Work #electrical
300 Sqmm Electrical Panel Glanding And Termination | Industrial Electrician Work
มุมมอง 6K7 หลายเดือนก่อน
300 Sqmm Electrical Panel Glanding And Termination | Industrial Electrician Work
3 Phase Motor Starter Connection | Industrial Electrical Work
มุมมอง 1907 หลายเดือนก่อน
3 Phase Motor Starter Connection | Industrial Electrical Work
SPN DB Cable Dressing And Connection | Power Distribution Board
มุมมอง 948 หลายเดือนก่อน
SPN DB Cable Dressing And Connection | Power Distribution Board
Industrial Motor Control Panel Tutorial | Electrician | Electrical Supervisor
มุมมอง 9K8 หลายเดือนก่อน
Industrial Motor Control Panel Tutorial | Electrician | Electrical Supervisor
Cable Gland Termination | Industrial Electrician Work | Electrical Panel Connection
มุมมอง 2888 หลายเดือนก่อน
Cable Gland Termination | Industrial Electrician Work | Electrical Panel Connection
Motor Controller Panel Wiring Connection | Industrial Electrical Work
มุมมอง 8919 หลายเดือนก่อน
Motor Controller Panel Wiring Connection | Industrial Electrical Work
500 KVA DG Cable Termination | Industrial Electrician Work | Electrical Room
มุมมอง 4049 หลายเดือนก่อน
500 KVA DG Cable Termination | Industrial Electrician Work | Electrical Room
Induction Motor Connection | Cable Gland Termination | Star Connection | Industrial Electrical Work
มุมมอง 1989 หลายเดือนก่อน
Induction Motor Connection | Cable Gland Termination | Star Connection | Industrial Electrical Work
How to Install Flame Proof Monochromatic Clean Room Light on Ceiling of Fire Proof Wall Panel
มุมมอง 1379 หลายเดือนก่อน
How to Install Flame Proof Monochromatic Clean Room Light on Ceiling of Fire Proof Wall Panel
BJI 218 LED PC wiring | Bajaj Industrial LED Connection | BJI 118 LED PC
มุมมอง 101ปีที่แล้ว
BJI 218 LED PC wiring | Bajaj Industrial LED Connection | BJI 118 LED PC
Sir bula lo
Sir live au
Good sir
Sir live a jau sir
Abhi kuchh nhi pta chala
Wait sir
Super sir
Nice sir
Hellooo sir can u explain it functions properly
Love you sir
❤
Nice
Email id
Yes sir send
aanandit151096 @ gmail . com remove space and send your updated cv
Please send me sir email id
aanandit151096@gmail.com
Email sent karo sir y bahar chale jaye
aanandit151096@gmail.com
Email id send karo sir
Nice sir
Email id send karo sir
aanandit151096@gmail.com
Email id send sir
aanandit151096@gmail.com
I. am hotel electrician but I am interested panel dressing work
Sir is time par time nhi milta h
Sir bahar n jaye sir
Happy diwali sir
Gjb sir
Hello sir number nhi diya apne
Apka number de diya hu required hone par contact kiya jayega
Sir rispons nhi diya sir please help me sir
Apka number aur apka qualification de diya hu supervisor ko Vo apse contact karenge jab required hoga
@@Electrical_Supervisor ok sir ap apna contact number de dijiye sir
Love you sir
Contact me
Nice 👍
Job location sir
Ambernath, Maharashtra, India
@@Electrical_Supervisor ok sir a jaye ge ap apna number send kar dijiye sir
Sir job chahiye
Electrical Engineer
Job location
Ambernath, Maharashtra
Sir job lgwa do diploma in Electrical Engineering
Kitni salary expect kar rahe ho ?
Aur work experience kitna hai ?
Diploma in Electrical Engineering
Cable 400 sq mm 3.5 cor
We use upto 300 sqmm 3.5C
400 sq mm cable 3.5 cor full Amps ???
How about electrical engineer
Electrical supervisor work under electrical engineer. And electricians work under electrical supervisor
Gland size used for 300 mm2 ?
63 mm
75
Es penal ka kiya naam hai
Thanks. Sar. ji
kidarka video a
Ultratech
Alag Alagse connection dekhateto bahut achxa hoga😅😅
Ok
Hellooo sir how can we learn it properly step by step
For theory, look at the Contactor diagram and then go to the controlling panel and do the practical with an experienced person.
Good luck
иι¢є
Right ✅️ ↔️ 👉 🔛 ➡️
How calculate that cable size
Method -1 We talk about 3 phase, heavy load, and Aluminium cable. According to Ampere load = near by available cable size Example-1, 60A load, here available cable near below 60 are 50 sqmm and 35 sqmm If the cable length below 100 mtrs we use 35 sqmm If the cable length above 100 mtrs we use 50 sqmm cable. Example-2, 300A load, here available cable near 300 are 300 sqmm and 240 sqmm If the cable length below 100 mtrs we use 240 sqmm cable and if the cable length above 100 mtrs we use 300 sqmm cable. You may use 2 run of 150 sqmm cable against 300 sqmm single cable. Similarly for 1000A load We use 3 run of 300 sqmm cable For 1600A load we use 5 run of 300 sqmm cable. For Copper cable multiply the Ampere by 1.2 and use above method. Method -2 For below 30A load and copper cable ...we just use Below 1KW load - 1.5 sqmm 2-3 KW load - 2.5 sqmm 3-5 KW load - 4 sqmm 5-9 KW load - 6 sqmm 9-12 KW load - 10 sqmm 12-16 KW load - 16 sqmm 16-25 KW load - 25 sqmm For aluminium cable Divide the load(KW) by 1.2 and use above method ☝️
If you want to use formula then I recommend use formula Power in KW(Load) = Volt x Current x power factor Example 3 phase load given 8 KW So, 8 KW = 8000W = 415(volt) x I(current) x 0.8 (pf) You Get I (current ) = 8000/(415*0.8) = 24A Now for safety I = 24 x 1.5 or 2 = 36 to 48 A Now search on google current capacity of Cu cable If you found 6 sqmm cable capacity = 33 A 10 sqmm cable capacity= 45 A And you calculate your current capacity= 36A to 48A According to your calculation 10 sqmm cable better for safety but you may use 6 sqmm cable too.
Apna number btao Bhai....
Number kis liye chahiye bhai
Full video link th-cam.com/video/v7B0rTeMvx4/w-d-xo.html
Schematic diagram per bhi video banao
InshAllah jald hi banaunga